  A production-design 115 MHz niobium quarter-wave cavity with a full stainless steel helium jacket has been built and tested as part of the R&D for the Rare Isotope Accelerator (RIA) driver linac. The two-gap cavity is designed to accelerate ions over the velocity range 0.14<β<0.24. Processing of the cavity RF surfaces, including high-pressure rinsing and assembly of the cavity with a moveable high-power RF coupler were all performed under clean room conditions. Cold test results including high-field cw operation, microphonics, and helium pressure sensitivity will be presented in this paper. Performance of a pneumatically actuated slow-tuner device suitable not only for this cavity but a number of other cavities required for RIA will also be discussed.  
THP06 Cold Tests of a Superconducting Co-Axial Half-Wave Cavity for RIA 608
 
  • M. Kelly
    ANL, Argonne, Illinois
  • J.D. Fuerst, M. Kedzie, K.W. Shepard
    ANL/Phys, Argonne, Illinois
 
  This paper reports cold tests of a superconducting niobium half-wave cavity with integral helium vessel, the design of which is suitable for production for the Rare Isotope Accelerator (RIA) driver linac. The cavity operates at 172 MHz and can provide more than 2 MV of accelerating voltage per cavity for ions with 0.24<β<0.37. Cavity RF surfaces were prepared using electropolishing, high-pressure rinsing and clean assembly. Measurements of Q0 show a residual RF surface resistance RS = 5 nΩs in both 2 K and 4 K operations. The cavity can be operated at 4.5 K with EAcc >10 MV/m (EPeak >30 MV/m). Performance exceeds RIA specifications of an input power of 12 Watts at 4.5 K and EAcc = 6.9 MV/m. RMS frequency jitter is only 1.6 Hz at EAcc = 8 MV/m and T = 4.5 K as determined from microphonics measurements in a realistic accelerator environment connected to the ATLAS refrigerator.  
Transparencies