A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Assmann, R.W.

 
Paper Title Page
TUP88 CLIC Magnet Stabilization Studies 483
 
  • S. Redaelli, R.W. Assmann, W. Coosemans, G. Guignard, D. Schulte, I. Wilson, F. Zimmermann
    CERN, Geneva
 
  One of the main challenges for future linear colliders is producing and colliding high energy e+e- beams with transverse spot sizes at the collision point in the nanometre range. Preserving small emittances along several kilometres of linac requires the lattice quadrupoles to be stable to the nanometre level. Even tighter requirements are imposed on the stability of the final focus quadrupoles, which have to be stable to a fraction of the colliding beam size to reliably steer the opposing beams in collision. The Compact LInear Collider (CLIC), presently under investigation at CERN, aims at colliding e+e- beams with a vertical spot size of 0.7 nm, at a centre-of-mass energy of 3 TeV. This requires a vertical stability to the 1.3 nm level for the 2600 linac quadrupoles and to the 0.2 nm level for the two final focus quadrupoles. The CLIC Stability Study has demonstrated for the first time that CLIC prototype quadrupoles can be stabilized to the 0.5 nm level in a normal working area on the CERN site. Detailed tracking simulations show that with this level of stability, approximately 70% of the CLIC design luminosity would be achieved. This paper summarizes the work and the achievements of the CLIC Stability Study.  
Transparencies