Author: Schlander, F.
Paper Title Page
TUPOTK026 ESS Elliptical Cryomodules Tests at Lund Test Stand 1261
 
  • C.G. Maiano, E. Asensi Conejero, N. Elias, P. Goudket, W. Hees, P. Pierini, L. Sagliano, F. Schlander, M.Y. Wang
    ESS, Lund, Sweden
  • D. Bocian, W. Gaj, P. Halczynski, M. Sienkiewicz, F.D. Skalka, J. Swierblewski, K.M. Wartak, M. Wartak
    IFJ-PAN, Kraków, Poland
 
  We present an overview and description of the elliptical cryomodules test activities at Lund Test Stand 2. During 2021 the test facility was commissioned with one prototype, and four series medium beta modules have now been successfully tested at ESS in Lund. This activity allowed the joint ESS and IFJ PAN team to develop all the procedures and the necessary automated tools for the different phases of the site acceptance test campaign (e.g. incoming inspections, coupler conditioning, cooldown strategies, tuning to resonance and electromagnetic/cryogenic performance verification). During the initial test period techniques for diagnostics of limiting mechanisms have been developed and improved up to a consolidated and mature state for the rest of the test campaign. Tests results and the initial statistics is presented and commented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOTK026  
About • Received ※ 07 June 2022 — Revised ※ 12 June 2022 — Accepted ※ 13 June 2022 — Issue date ※ 16 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOST038 On-Site Transport and Handling Tests of Cryomodules for the European Spallation Source 2527
 
  • F. Schlander, A. Bignami, N. Gazis
    ESS, Lund, Sweden
 
  The cryomodules for the superconducting Linac of the European Spallation Source ’ ESS are now arriving in a steady stream and the long-distance transport requirements are well understood. For the on-site transportation, handling and storage, several challenges have risen, including the intermediate storage of cryomodules before testing and/or installation. In comparison to the long-distance transports, the cryomodule on-site transports and respective handling until installation take place with specialised and limited transport protection. This requires additional measures and tests of those handling steps with extended diagnostics, to make sure that handling and transport refrains from damages on the last mile. Those handling procedures and executed tests will be described in this contribution.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOST038  
About • Received ※ 07 June 2022 — Revised ※ 15 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 25 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)