Author: Sabbatini, L.
Paper Title Page
MOPOMS019 The New SPARC_LAB RF Photo-Injector 671
 
  • D. Alesini, M.P. Anania, M. Bellaveglia, A. Biagioni, F. Cardelli, G. Costa, M. Del Franco, G. Di Pirro, L. Faillace, M. Ferrario, G. Franzini, A. Gallo, A. Giribono, L. Piersanti, L. Sabbatini, A. Stella, A. Vannozzi
    INFN/LNF, Frascati, Italy
  • A. Battisti, E. Chiadroni, G. Di Raddo, A. Liedl, V.L. Lollo, L. Pellegrino, R. Pompili, S. Romeo, V. Shpakov, C. Vaccarezza, F. Villa
    LNF-INFN, Frascati, Italy
  • M. Carillo, E. Chiadroni
    Sapienza University of Rome, Rome, Italy
  • A. Cianchi, M. Galletti
    Università di Roma II Tor Vergata, Roma, Italy
 
  A new RF photo-injector has been designed, realized and successfully installed at the SPARC_LAB facility (INFN-LNF, Frascati, Rome). It is based on a 1.6 cell RF gun fabricated with the new brazing free technology recently developed at the National Laboratories of Frascati. The electromagnetic design has been optimized to have a full compensation of the dipole and quadrupole field components introduced by the coupling hole with an improvement of the effective pumping speed with two added pumping ports. The gun is overcoupled (\beta=2) to reduce the filling time and to allow the operation with short RF pulses. The overall injector integrates a new solenoid with a remote control of the transverse position and a variable skew quadrupole for the compensation of residual quadrupole field components. It also allows an on axis laser injection system with the last mirror in air, and the possibility of a future integration of an X/C band cavity linearizer. In the paper we report the main characteristics of the electromagnetic and mechanical design and the low and high power test results that shows the extremely good perfomances of the new device.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOMS019  
About • Received ※ 07 June 2022 — Revised ※ 13 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 26 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOPT061 Status and Commissioning of the First X-Band RF Source of the TEX Facility 1148
 
  • F. Cardelli, D. Alesini, M. Bellaveglia, S. Bini, M. Ceccarelli, C. Di Giulio, A. Falone, G. Franzini, A. Gallo, L. Piersanti, L. Sabbatini
    INFN/LNF, Frascati, Italy
  • B. Buonomo, G. Catuscelli, R. Ceccarelli, A. Cecchinelli, R. Clementi, E. Di Pasquale, A. Liedl, D. Moriggi, G. Piermarini, S. Pioli, S. Quaglia, L.A. Rossi, M. Scampati, G. Scarselletta, S. Strabioli, S. Tocci, R. Zarlenga
    LNF-INFN, Frascati, Italy
 
  In 2021 started the commissioning of the TEX (Test stand for X-band) facility at the Frascati National laboratories of INFN. This facility has been founded in the framework of the LATINO (Laboratory in Advanced Technologies for INnOvation) project. The current facility layout includes an high power X-band (11.994 GHz) RF source, realized in collaboration with CERN, which will be used for validation and development of the X-band RF high gradient technology in view of the EuPRAXIA@SPARC_LAB project. The RF source is based on a CPI VKX8311 Klystron and a solid state ScandiNova k400 modulator to generate a maximum RF output power of 50 MW at 50 Hz, that will be mainly used for accelerating structure conditioning and waveguide components testing. In this paper the layout, the installation, commissioning and stability measurements of this source are described in detail. The test stand will be soon operative and ready to test the first X-band accelerating structure prototype.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOPT061  
About • Received ※ 08 June 2022 — Revised ※ 11 June 2022 — Accepted ※ 15 June 2022 — Issue date ※ 10 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOST015 Commissioning and First Results of an X-Band LLRF System for TEX Test Facility at LNF-INFN 876
 
  • L. Piersanti, D. Alesini, M. Bellaveglia, S. Bini, B. Buonomo, F. Cardelli, C. Di Giulio, E. Di Pasquale, M. Diomede, L. Faillace, A. Falone, G. Franzini, A. Gallo, G. Giannetti, A. Liedl, D. Moriggi, S. Pioli, S. Quaglia, L. Sabbatini, M. Scampati, G. Scarselletta, A. Stella, S. Tocci, L. Zelinotti
    LNF-INFN, Frascati, Italy
 
  Funding: Latino is a project co-funded by Regione Lazio within POR-FESR 2014-2020 program
In the framework of LATINO project (Laboratory in Advanced Technologies for INnOvation) funded by Lazio regional government, the commissioning of the TEst stand for X-band (TEX) facility has started in 2021 at Frascati National Laboratories of INFN. Born as a collaboration with CERN to test high gradient accelerating structures, during 2022 TEX aims at feeding the first EuPRAXIA@SPARC_LAB X-band structure prototype. During 2021 the commissioning has been successfully carried out up to 48 MW. The power unit is driven by an X-band low level RF system, that employs a commercial S-band (2.856 GHz) Libera digital LLRF (manufactured by Instrumentation Technologies), with an up/down conversion stage and a reference generation and distribution system able to produce coherent frequencies for the American S-band and European X-band (11.994 GHz), both designed and realized at LNF. The performance of the system, with a particular focus on amplitude and phase resolution, together with klystron and driver amplifier jitter measurements, will be reviewed in this paper. Moreover, considerations on its suitability and main limitations in view of EuPRAXIA@SPARC_LAB project will be discussed.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOST015  
About • Received ※ 20 May 2022 — Revised ※ 13 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 28 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOMS012 Explorative Studies of an Innovative Superconducting Gantry 2966
 
  • M.G. Pullia, M. Donetti, E. Felcini, G. Frisella, A. Mereghetti, A. Mirandola, A. Pella, S. Savazzi
    CNAO Foundation, Pavia, Italy
  • E. Benedetto
    SEEIIST, Geneva, Switzerland
  • L. Dassa, M. Karppinen, D. Perini, D. Tommasini, M. Vretenar
    CERN, Meyrin, Switzerland
  • E. De Matteis, L. Rossi
    INFN/LASA, Segrate (MI), Italy
  • C. Kurfürst, M.T.F. Pivi, M. Stock
    EBG MedAustron, Wr. Neustadt, Austria
  • S. Mariotto, M. Prioli
    INFN-Milano, Milano, Italy
  • L. Piacentini, A. Ratkus, T. Torims, J. Vilcans
    Riga Technical University, Riga, Latvia
  • L. Sabbatini, A. Vannozzi
    LNF-INFN, Frascati, Italy
  • S. Uberti
    Università di Brescia, Brescia, Italy
 
  Funding: This study was (partially) supported by the European Union’s Horizon 2020 research and innovation programme under grant agreement no. 101008548 (HITRIplus).
The Heavy Ion Therapy Research Integration plus (HITRIplus) is a European project that aims to integrate and propel research and technologies related to cancer treatment with heavy ions beams. Among the ambitious goals of the project, a specific work package includes the design of a gantry for carbon ions, based on superconducting magnets. The first milestone to achieve is the choice of the fundamental gantry parameters, namely the beam optics layout, the superconducting magnet technology, and the main user requirements. Starting from a reference 3T design, the collaboration widely explored dozens of possible gantry configurations at 4T, aiming to find the best compromise in terms of footprint, capital cost, and required R&D. We present here a summary of these configurations, underlying the initial correlation between the beam optics, the mechanics, and the main superconducting dipoles design: the bending field (up to 4 T), combined function features (integrated quadrupole), magnet aperture (up to 90 mm), and angular length (30°-45°). The resulting main parameters are then listed, compared, and used to drive the choice of the best gantry layout to be developed in HITRIplus.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOMS012  
About • Received ※ 20 May 2022 — Revised ※ 12 June 2022 — Accepted ※ 13 June 2022 — Issue date ※ 16 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)