Paper |
Title |
Page |
MOPOMS042 |
Comparison Between Run 2 TID Measurements and FLUKA Simulations in the CERN LHC Tunnel of the Atlas Insertion Region |
732 |
|
- D. Prelipcean, K. Biłko, F. Cerutti, A. Ciccotelli, D. Di Francesca, R. García Alía, B. Humann, G. Lerner, D. Ricci, M. Sabaté-Gilarte
CERN, Meyrin, Switzerland
- B. Humann
TU Vienna, Wien, Austria
|
|
|
In this paper we present a systematic benchmark between the simulated and the measured data for the radiation monitors useful for Radiation to Electronics (R2E) studies at the Large Hadron Collider (LHC) at CERN. For this purpose, the radiation levels in the main LHC tunnel on the right side of the Interaction Point 1 (ATLAS detector) are simulated using the FLUKA Monte Carlo code and compared against Total Ionising Dose (TID) measurements performed with the Beam Loss Monitoring (BLM) system, and 180 m of Distributed Optical Fibre Radiation Sensor (DOFRS). Considering the complexity and the scale of the simulations as well as the variety of the LHC operational parameters, we find a generally good agreement between measured and simulated radiation levels, typically within a factor of 2 or better.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOMS042
|
|
About • |
Received ※ 08 June 2022 — Revised ※ 23 June 2022 — Accepted ※ 26 June 2022 — Issue date ※ 09 July 2022 |