Paper | Title | Page |
---|---|---|
MOPOPT006 | Characterization of the Electron Beam Visualization Stations of the ThomX Accelerator | 240 |
SUSPMF083 | use link to see paper's listing under its alternate paper code | |
|
||
Funding: Research Agency under the Equipex convention ANR-10-EQPX-0051. We present an overview of the diagnostics screens stations - named SSTs - of the ThomX compact Compton source. ThomX is a compact light source based on Compton backscattering. It features a linac and a storage ring in which the electrons have an energy of 50 MeV. Each SST is composed of three screens, a YAG:Ce screen and an Optical Transition Radiation (OTR) screen for transverse measurements and a calibration target for magnification and resolution characterisation. The optical system is based on commercial lenses that have been reverse-engineered. An Arduino is used to control both the aperture and the focus remotely, while the magnification must be modified using an external motor. We report on the overall performance of the station as measured during the first steps of beam commissioning and on the optical system remote operations. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOPT006 | |
About • | Received ※ 20 May 2022 — Revised ※ 10 June 2022 — Accepted ※ 14 June 2022 — Issue date ※ 17 June 2022 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEOYSP2 | First Electron Beam of the ThomX Project | 1632 |
|
||
Funding: The present work is financed by the French National Research Agency (ANR) under the Equipex program ANR-10-EQPX-0051. The ThomX accelerator beam commissioning phase is now ongoing. The 50 MeV electron accelerator complex consists of a 50 MeV linear accelerator and a pulsed mode ring. It is dedicated to the production of X-rays by Compton backscattering. The performance of the beam at the interaction point is demanding in terms of emittance, charge, energy spread and transverse size. The choice of an undamped ring in pulsed mode also stresses the performance of the beam from the linear accelerator. Thus, commissioning includes a beam based alignment and a simulation/experimental matching procedure to reach the X-ray beam requirements. We will present the first 50 MeV electron beam obtained with ThomX and its characteristics. on behalf of the ThomX collaboration : ThomX collaboration, https://thomx.ijclab.in2p3. fr/collaboration-thomx/, [Online; accessed 19-May- 2022]. |
||
![]() |
Slides WEOYSP2 [80.558 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-WEOYSP2 | |
About • | Received ※ 08 June 2022 — Revised ※ 21 June 2022 — Accepted ※ 04 July 2022 — Issue date ※ 06 July 2022 | |
Cite • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |