Author: Kittimanapun, K.
Paper Title Page
WEPOTK052 Beam Coupling Impedance Study and Its Database of Siam Photon Source Storage Ring 2177
 
  • N. Juntong, T. Chanwattana, S. Jummunt, K. Kittimanapun, T. Phimsen, W. Promdee, T. Pulampong
    SLRI, Nakhon Ratchasima, Thailand
 
  Since the Siam Photon Source (SPS) had an electron beam energy upgraded from 1.0 GeV to 1.2 GeV in 2005, the storage ring impedance measurements were done once in 2007. Two insertion magnet devices have been installed in the SPS storage ring during June to August 2013. There are several vacuum components added to the storage ring; these affect the ring impedance. Quantitative understanding of instabilities requires detailed knowledge of the impedance of the ring. For this purpose, the development of an impedance database is a necessity, where the wake potentials of each vacuum component are kept and maintained in a standard format. The self-describing data sets (SDDS) file format will be utilized to record components wake potentials. The wake potentials of each vacuum component can be obtained from a particle tracking simulation; a CST particle studio program will be used in the simulation process. The wake potentials can also be included in a beam dynamic tracking program such as ELEGANT to observe beam behaviors with these instabilities and find a curing means. The study results will be presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-WEPOTK052  
About • Received ※ 19 May 2022 — Revised ※ 13 June 2022 — Accepted ※ 14 June 2022 — Issue date ※ 25 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOTK014 100 keV Electron Source Design for the New 3 GeV Synchrotron Facility in Thailand 2800
 
  • N. Juntong, S. Bootiew, T. Chanwattana, Ch. Dhammatong, S. Jummunt, K. Kittimanapun, W. Phacheerak
    SLRI, Nakhon Ratchasima, Thailand
  • K. Manasatitpong
    Synchrotron Light Research Institute (SLRI), Muang District, Thailand
 
  The Synchrotron Light Research Institute (SLRI) is developing a new synchrotron light source with an electron beam energy of 3 GeV. The DC thermionic electron gun was chosen because it is simple and less cost. The design process is well known. The operation is more stable compared to the RF gun. The cathode Y-646B was considered because it had already been used at the old synchrotron machine and the possibility of sharing the stock outweighs other disadvantages. Moreover, it is used in many synchrotron facilities, so it is easy to find references. The present of the focusing electrode was discussed. The focusing electrode will increase the complexity of the gun, but it is necessary to get a high-quality beam from the gun. The designed electron gun can produce 1.1 A beams current with the normalized emittance of 0.910 Pi·mm·mrad, which satisfied the requirement of the linac injector. The design and study results will be discussed in this report.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOTK014  
About • Received ※ 20 May 2022 — Accepted ※ 14 June 2022 — Issue date ※ 29 June 2022  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOTK015 Solid-State Pulsed Power Supply for a 100 keV Electron Source of the New Synchrotron Facility in Thailand 2803
 
  • W. Phacheerak, S. Bootiew, T. Chanwattana, Ch. Dhammatong, N. Juntong, K. Kittimanapun
    SLRI, Nakhon Ratchasima, Thailand
  • K. Manasatitpong
    Synchrotron Light Research Institute (SLRI), Muang District, Thailand
 
  The new synchrotron light source project in Thailand will utilize a thermionic DC electron gun. The maximum operation of the gun is 100 keV, which requires a pulsed power supply of 100kV. The present synchrotron machine uses a conventional design of the gun power supply. To improve the high voltage pulsed quality, the solid-state design of the gun power supply is utilized. The output pulse width can be adjusted easily and the droop is less compared to the conventional design. The designed output of 100 kV amplitude with 5 µs pulsed width can be achieved with this design. It also produces a less droop of 1.8%. The design process and results will be presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOTK015  
About • Received ※ 08 June 2022 — Revised ※ 13 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 26 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)