Author: Hartmann, P.
Paper Title Page
MOPOPT003 Studying Instabilities in the Canadian Light Source Storage Ring Using the Transverse Feedback System 230
SUSPMF081   use link to see paper's listing under its alternate paper code  
 
  • S.J. Martens
    University of Saskatchewan, Saskatoon, Canada
  • D. Bertwistle, M.J. Boland
    CLS, Saskatoon, Saskatchewan, Canada
  • P. Hartmann
    DELTA, Dortmund, Germany
 
  The Transverse Feedback system at the Canadian Light Source can identify, categorize, and mitigate against periodic instabilities that arise in the storage ring beam. By quickly opening and closing the feedback loop, previously mitigated instabilities will be allowed to grow briefly before being damped by the system. The resulting growth in the beam oscillation amplitude curve can be analyzed to determine growth/damp rates and modes of the coupled bunch oscillations. Further measurements can be collected via active excitement of modes rather than passive growth. These Grow/damp and Excite/Damp curves have been collected and analyzed for various storage ring beam properties, including beam energy, machine chromaticity, and in-vacuum insertion device gap widths.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOPT003  
About • Received ※ 08 June 2022 — Revised ※ 14 June 2022 — Accepted ※ 15 June 2022 — Issue date ※ 09 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)