Author: Amirkhanyan, Z.
Paper Title Page
MOPOTK003 Absorbed Dose Characteristics for Irradiation Experiments at AREAL 5 MeV Electron Linac 429
 
  • V.G. Khachatryan, Z. Amirkhanyan, H. Davtyan, A. Grigoryan, B. Grigoryan, M. Ivanyan, V.H. Petrosyan, A. Vardanyan, A.S. Yeremyan
    CANDLE SRI, Yerevan, Armenia
  • A. Grigoryan
    YSU, Yerevan, Armenia
 
  Existing electron photogun facility at the CANDLE SRI currently can provide electron beam with the energy up to 5 MeV. The beam is being used as an irradiation source in the number of material science and life science experiments. Performed beam particle tracking simulations along with intensive application of the beam diagnostic instruments (bending magnet, YAG stations, Faraday cups) allow control of the experimental samples’ irradiation parameters, particularly exposure times for given dose as well as absorbed dose spatial distribution. Direct application of the electron beam for the irradiation experiments allows achievement of high absorbed dose. For the calculation of the irradiation parameters of the experimental samples’ particle transport simulation results should be combined with the beam current measurements by Faraday Cup (FC). Dose measurements and the comparison with numerical simulations using various initial parameters (Transverse size, divergence and energy spread) permit to pin down their actual values.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOTK003  
About • Received ※ 03 June 2022 — Revised ※ 10 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 02 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOMS010 Heating and Beam Impact of High Intensity Exit Windows for FLASHlab@PITZ 2958
 
  • Z. Amirkhanyan
    CANDLE SRI, Yerevan, Armenia
  • Z. Aboulbanine, M. Groß, M. Krasilnikov, T. Kuhl, X.-K. Li, R. Niemczyk, A. Oppelt, S. Philipp, H.J. Qian, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
  • M. Schmitz
    DESY, Hamburg, Germany
 
  The high-brightness electron beam at the Photo Injector Test facility at DESY in Zeuthen (PITZ) is being prepared for use in dosimetry experiments and for the study of biological effects in thin samples. This is part of the preparations for FLASHlab@PITZ which is going to be an R&D platform for FLASH and VHEE radiation therapy and radiation biology. These studies require precise information on the electron beam parameters downstream of the exit window, such as the scattering angle and the energy spectrum of the particles as well as the thermal load on the exit window. A Titanium window is compared with a DESY Graphite window design. Heat deposition in the window by a single 22MeV / 1nC electron bunch of various size, its scattering and energy spectrum due to passage through the window are calculated by means of the Monte Carlo program FLUKA. Time resolved temperature profiles, as generated by the passage of 1ms long electron pulse trains with up to 4500 single pulses, each of them between 0.1 and 60ps long, are calculated with a self-written FEM code.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOMS010  
About • Received ※ 08 June 2022 — Revised ※ 13 June 2022 — Accepted ※ 15 June 2022 — Issue date ※ 30 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOMS008 Physics Design of Electron Flash Radiation Therapy Bemaline at PITZ 2954
 
  • X.-K. Li, Z. Aboulbanine, Z. Amirkhanyan, M. Groß, M. Krasilnikov, A. Lueangaramwong, R. Niemczyk, A. Oppelt, S. Philipp, H.J. Qian, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
  • G. Loisch, F. Obier, M. Schmitz
    DESY, Hamburg, Germany
 
  The Photo Injector Test facility at DESY in Zeuthen (PITZ) is preparing an R&D platform for electron FLASH radiotherapy, very high energy electron (VHEE) radiotherapy and radiation biology based on its unique beam parameters: ps scale bunches with up to 5 nC bunch charge at MHz bunch repetition rate in bunch trains of up to 1 ms in length repeating at 10 Hz. This platform is called FLASHlab@PITZ. The PITZ beam is routinely accelerated to 22 MeV, with a possible upgrade to 250 MeV for VHEE radiotherapy in the future. The 22 MeV beam will be used for dosimetry experiments and studying biological effects in thin samples in the next years. A new beamline to extract and match the beam to the experimental station is under physics design. The main features include: an achromatic dogleg to extract the beam from the PITZ beamline; a sweeper to scan the beam across the sample within 1 ms for tumor painting studies; and an imaging system to keep the beam size small at the sample after scattering in the exit window while maintaining the scan range of the sweeper. In this paper, the beam dynamics with bunch charges from 10 pC to 5 nC in and the preparation of the new beamline will be presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOMS008  
About • Received ※ 08 June 2022 — Revised ※ 14 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 17 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)