JACoW logo

Journals of Accelerator Conferences Website (JACoW)

JACoW is a publisher in Geneva, Switzerland that publishes the proceedings of accelerator conferences held around the world by an international collaboration of editors.


RIS citation export for MOPOST021: ReAccelerator Upgrade, Commissioning and First Experiments at the National Superconducting Cyclotron Laboratory (NSCL) / Facility for Rare Isotope Beams (FRIB)

TY  - CONF
AU  - Villari, A.C.C.
AU  - Arend, B.
AU  - Bollen, G.
AU  - Crisp, D.B.
AU  - Davidson, K.D.
AU  - Fukushima, K.
AU  - Henriques, A.I.
AU  - Holland, K.
AU  - Kim, S.H.
AU  - Lapierre, A.
AU  - Maruta, T.
AU  - Morris, D.G.
AU  - Morrissey, D.J.
AU  - Nash, S.
AU  - Ostroumov, P.N.
AU  - Plastun, A.S.
AU  - Priller, J.
AU  - Sherrill, B.M.
AU  - Steiner, M.
AU  - Walker, R.
AU  - Zhang, T.
AU  - Zhao, Q.
ED  - Zimmermann, Frank
ED  - Tanaka, Hitoshi
ED  - Sudmuang, Porntip
ED  - Klysubun, Prapong
ED  - Sunwong, Prapaiwan
ED  - Chanwattana, Thakonwat
ED  - Petit-Jean-Genaz, Christine
ED  - Schaa, Volker R.W.
TI  - ReAccelerator Upgrade, Commissioning and First Experiments at the National Superconducting Cyclotron Laboratory (NSCL) / Facility for Rare Isotope Beams (FRIB)
J2  - Proc. of IPAC2022, Bangkok, Thailand, 12-17 June 2022
CY  - Bangkok, Thailand
T2  - International Particle Accelerator Conference
T3  - 13
LA  - english
AB  - The reaccelerator ReA is a state-of-the-art super-conducting linac for reaccelerating rare isotope beams produced via inflight fragmentation or fission and subse-quent beam stopping. ReA was subject of an upgrade that increased its final beam energy from 3 MeV/u to 6 MeV/u for ions with charge over mass equal to 1/4. The upgrade included a new room-temperature rebuncher after the first section of acceleration, a new β = 0.085 QWR cryomodule and two new beamlines in a new ex-perimental vault. During commissioning, beams were accelerated with near 100 percent transport efficiency through the linac and delivered through beam transport lines. Measured beam characteristics match those calcu-lated. Following commissioning, stable and long living rare isotope beams from a Batch Mode Ion Source (BMIS) were accelerated and delivered to experiments. This con-tribution will briefly describe the upgrade, and results from beam commissioning and beam delivery for experi-ments.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 101
EP  - 103
KW  - cryomodule
KW  - experiment
KW  - MMI
KW  - linac
KW  - ion-source
DA  - 2022/07
PY  - 2022
SN  - 2673-5490
SN  - 978-3-95450-227-1
DO  - doi:10.18429/JACoW-IPAC2022-MOPOST021
UR  - https://jacow.org/ipac2022/papers/mopost021.pdf