Paper | Title | Page |
---|---|---|
MOPAB280 | Split Ring Resonator Experiment - Simulation Results | 888 |
|
||
Funding: Supported by "Karlsruhe School of Elementary and Astroparticle Physics: Science and Technology (KSETA)" and European Union’s Horizon 2020 Research and Innovation programme. FLUTE (Ferninfrarot Linac- Und Test-Experiment) is a compact linac-based test facility for accelerator and diagnostics R&D. An example for a new accelerator diagnostics tool currently studied at FLUTE is the split-ring-resonator (SRR) experiment, which aims to measure the longitudinal bunch profile of fs-scale electron bunches. Laser-generated THz radiation is used to excite a high frequency oscillating electromagnetic field in the SRR. Particles passing through the SRR gap are time-dependently deflected in the vertical plane, which allows a vertical streaking of an electron bunch. This principle allows a diagnosis of the longitudinal bunch profile in the femtosecond time domain and will be tested at FLUTE. This contribution presents an overview of the SRR experiment and the results of various tracking simulations for different scenarios as a function of laser pulse length and bunch charge. Based on these results possible working points for the experiments at FLUTE will be proposed. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB280 | |
About • | paper received ※ 19 May 2021 paper accepted ※ 21 June 2021 issue date ※ 01 September 2021 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPAB103 | Systematic Beam Parameter Studies at the Injector Section of FLUTE | 2837 |
|
||
Funding: This work is supported by the DFG-funded Doctoral School "Karlsruhe School of Elementary and Astroparticle Physics: Science and Technology (KSETA)" FLUTE (Ferninfrarot Linac- und Test-Experiment) is a compact linac-based test facility for accelerator R&D and source of intense THz radiation for photon science. In preparation for the next experiments, the electron beam of the injector section of FLUTE has been characterized. In systematic studies the electron beam parameters, e.g., beam energy and emittance, are measured with several diagnostic systems. This knowledge allows the establishment of different operation settings and the optimization of electron beam parameters for future experiments. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB103 | |
About • | paper received ※ 19 May 2021 paper accepted ※ 01 September 2021 issue date ※ 13 August 2021 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |