Paper |
Title |
Page |
MOPAB329 |
Operations of Copper Cavities at Cryogenic Temperatures |
1020 |
|
- H. Wang, U. Ratzinger, M. Schuett
IAP, Frankfurt am Main, Germany
|
|
|
How the anomalous skin effect by copper affects the efficiency of copper- cavities will be studied in the experiment, especially at lower temperatures. The accurate quality factor Q and resonant frequency of three coaxial cavities will be measured over the temperature range from 300 to 22 K. The three coaxial cavities have the same structure, but different lengths, which correspond to resonant frequencies: around 100 MHz, 220 MHz and 340 MHz. The motivation is to check the feasibility of an efficient pulsed, liquid nitrogen cooled ion linac.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB329
|
|
About • |
paper received ※ 19 May 2021 paper accepted ※ 07 June 2021 issue date ※ 02 September 2021 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|