TUPAB168 | Beam Commissioning of a 325 MHz Proton IH-DTL at XiPAF | 1777 |
|
||
The Inter-Digital H-mode Drift Tube Linac (IH-DTL) is widely used as the main component of injectors for medical synchrotrons. This paper describes the beam commissioning of a compact 325 MHz IH-DTL with modified KONUS beam dynamics at Tsinghua University (THU). This IH-DTL accelerates the proton beam from 3 MeV to 7 MeV in 1m. The average energy of the beam is 7.0 MeV with the energy spread range of -0.6 MeV to 0.3 MeV. The output transverse normalized RMS emittance of the beam is 0.58 (x)/0.58 (y) pi mm mrad with the input emittance of 0.43 (x)/0.37 (y) pi mm mrad. The beam test results show good agreement with the beam dynamics design. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB168 | |
About • | paper received ※ 08 May 2021 paper accepted ※ 16 June 2021 issue date ※ 14 August 2021 | |