Author: Poirier, F.
Paper Title Page
WEPAB029 Challenges for the Interaction Region Design of the Future Circular Collider FCC-ee 2668
 
  • M. Boscolo, A. Ciarma, F. Fransesini, L. Pellegrino
    INFN/LNF, Frascati, Italy
  • N. Bacchetta
    INFN- Sez. di Padova, Padova, Italy
  • M. Benedikt, H. Burkhardt, M.A. Jones, R. Kersevan, M. Lueckhof, E. Montbarbon, K. Oide, L. Watrelot, F. Zimmermann
    CERN, Meyrin, Switzerland
  • L. Brunetti, M. Serluca
    IN2P3-LAPP, Annecy-le-Vieux, France
  • M. Dam
    NBI, København, Denmark
  • M. Koratzinos
    MIT, Cambridge, Massachusetts, USA
  • M. Migliorati
    INFN-Roma1, Rome, Italy
  • A. Novokhatski, M.K. Sullivan
    SLAC, Menlo Park, California, USA
  • F. Poirier
    CNRS - DR17, RENNES, France
 
  Funding: This work was partially supported by the EC HORIZON 2020 project FCC-IS, grant agreement n.951754, and by the U. S. Department of Energy, Office of Science, under Contract No. DE-AC02-76SF-00515.
The FCC-ee is a proposed future high-energy, high-intensity and high precision lepton collider. Here, we present the latest developments for the FCC-ee interaction regions, which shall ensure optimum conditions for the particle physics experiments. We discuss measures of background reduction and a revised interaction region layout including a low impedance compact beam chamber design. We also discuss the possible impact of the radiation generated in the interaction region including beamstrahlung.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB029  
About • paper received ※ 11 May 2021       paper accepted ※ 23 June 2021       issue date ※ 30 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB276 Investigation on the injection of the Arronax Cyclotron 70XP 873
 
  • F. Poirier, F. Bulteau-Harel, T. Durand, X. Goiziou, C. Koumeir, C. Lassalle, H. Trichet
    Cyclotron ARRONAX, Saint-Herblain, France
  • F. Haddad
    SUBATECH, Nantes, France
 
  Funding: This work is supported by grants from the ANR program "Investissements d’Avenir", n°ANR-11-EQPX-0004, n°ANR-11-LABX-18-01 and n°ANR-16-IDE-0007 and by a PhD scholarship from CNRS/IN2P3.
A 70 MeV cyclotron is being used at the Arronax GIP (Interest Public Group), France, for various types of R&D on nuclear, biological and chemical reactions with beams and radioisotopes production. In order to adapt its usage for experiments and users demands of high peak intensity, above an equivalent average of a few µA, the injection is being adapted. Several studies are thus being performed in this section. These include the newly installed chopper-based system and the injection collimator. This paper details the various studies, specifically the signal purity obtained in the pulsed mode. A mode particularly adapted for flash irradiation.
 
poster icon Poster MOPAB276 [2.522 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB276  
About • paper received ※ 19 May 2021       paper accepted ※ 23 June 2021       issue date ※ 15 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB277 Installation, Use and Follow-Up of an Emittance-Meter at the Arronax Cyclotron 70XP 877
 
  • F. Poirier, R. Bellamy, F. Bulteau-Harel, C. Castel, T. Durand, X. Goiziou, F. Haddad, C. Koumeir, R. Lelièvre, G. Mechin, L. Perrigaud, J. Poudevigne, H. Trichet
    Cyclotron ARRONAX, Saint-Herblain, France
  • T. Adam, P.G. Graehling, M. Heine, C. Maazouzi, F.R. Osswald, E.K. Traykov
    IPHC, Strasbourg Cedex 2, France
  • A. Dinkov, S. Wurth
    IJCLab, ORSAY, France
  • F. Haddad
    SUBATECH, Nantes, France
 
  Funding: This work is supported by grants from the ANR program "Investissements d’Avenir", n°ANR-11-EQPX-0004, n°ANR-11-LABX-18-01 and n°ANR-16-IDE-0007 and by a PhD scholarship from CNRS/IN2P3.
The 70 MeV cyclotron group of the Arronax GIP (Interest Public Group), France, foresees to increase its beam intensity on target. For this, several beam studies are being performed in the various sections of the accelerator including the injection. Thus, an Allison-type emittance-meter has been installed in this section above the cyclotron and downstream a quadrupole triplet. Installation and the first results of a campaign of measurements are presented including high intensity runs, up to 1 mA for 40 keV H ions. The emittance-meter is expected to be used with several accelerators throughout the world. Therefore, a strategy on the follow-up of the activation of sample materials used in the equipment is being established and is described in the paper.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB277  
About • paper received ※ 17 May 2021       paper accepted ※ 27 May 2021       issue date ※ 12 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)