Paper |
Title |
Page |
WEPAB015 |
Comparison of Different Matching Device Field Profiles for the FCC-ee Positron Source |
2617 |
|
- Y. Zhao, L. Ma
SDU, Shandong, People’s Republic of China
- B. Auchmann, P. Craievich, J. Kosse, R. Zennaro
PSI, Villigen PSI, Switzerland
- I. Chaikovska, R. Chehab
Université Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France
- S. Döbert, A. Latina
CERN, Geneva, Switzerland
- P.V. Martyshkin
BINP SB RAS, Novosibirsk, Russia
|
|
|
In this report, we compared different matching device field profiles for the FCC-ee positron source. The matching device is used to capture positrons with magnetic field. A flux concentrator was designed with a conical inner chamber. A smaller aperture and a larger aperture were studied. An analytic field profile was also studied using an adiabatic formula. The peak field of the analytic profile as well as beam and target parameters was optimised to achieve a maximum positron yield. A safe energy deposition in the target was guaranteed by requiring a constraint on the deposited power and peak energy deposition density.
|
|
|
Poster WEPAB015 [3.066 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB015
|
|
About • |
paper received ※ 15 May 2021 paper accepted ※ 23 June 2021 issue date ※ 30 August 2021 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPAB021 |
Status of VEPP-5 Injection Complex |
3796 |
|
- F.A. Emanov, A.V. Andrianov, K.V. Astrelina, V.V. Balakin, A.M. Barnyakov, A.M. Batrakov, O.V. Belikov, D.E. Berkaev, Y.M. Boimelshtain, D. Bolkhovityanov, A. Butakov, A.R. Frolov, G.V. Karpov, A.S. Kasaev, A.A. Kondakov, N.Kh. Kot, E.S. Kotov, G.Y. Kurkin, R.M. Lapik, N.N. Lebedev, A.E. Levichev, Yu.I. Maltseva, P.V. Martyshkin, S.V. Motygin, A.A. Murasev, V. Muslivets, D.A. Nikiforov, A.V. Pavlenko, A.M. Pilan, Yu.A. Rogovsky, S.L. Samoylov, A.G. Tribendis, S. Vasiliev, V.D. Yudin
BINP SB RAS, Novosibirsk, Russia
|
|
|
VEPP-5 injection complex is being put into operation as beam source of VEPP-2000 and VEPP-4 colliders at the end of 2016. Since then injection complex demonstrated maximum positron storage rate 1.7·1010 e+/s and stable operation at the energy of 430 MeV. Latest operation results and prospects are presented.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2021-THPAB021
|
|
About • |
paper received ※ 20 May 2021 paper accepted ※ 27 July 2021 issue date ※ 27 August 2021 |
|