Author: Li, Z.S.
Paper Title Page
TUXC08 Simulation and Beam Experiments of a Multi-Harmonics Buncher in SSC-Linac 1319
 
  • Q.Y. Kong, H. Du, P. Jin, L. Jing, X.N. Li, Z.S. Li, Zh. Liu, J.W. Xia, X. Yin, Y. Zhang
    IMP/CAS, Lanzhou, People’s Republic of China
 
  Funding: This work was supported by the National Natural Science Foundation of China(No. 11375243) and Guangdong Innovative and Entrepreneurial Research Team Program(No.2016ZT06G373).
A compact dual-gap Multi-Harmonics Buncher has been successfully used at the SSC-Linac, a linear accelerator dedicates to beam injection into SSC in HIRFL. SSC-Linac operates at 53.667MHz, which is forth time of the RF frequency of the SSC. In order to increase the longitudinal capture efficiency, and enhance the current out of SSC, an independent MHB(Multi-Harmonics Buncher) had been installed into the LEBT of SSC-Linac. The fundamental frequency of the MHB is 13.417MHz. The buncher adopts the mechanical structure of dual-gap and sawtooth waveform is generated by multi-harmonics synthetic technology. Beam performance simulation with MHB have been done with code BEAMPATH. Besides, 84Kr14+ beam has been bunched successfully using the MHB in our experiments, the maximum bunch efficiency of 86.1% has been measured in experiments.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUXC08  
About • paper received ※ 31 May 2021       paper accepted ※ 12 July 2021       issue date ※ 11 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)