Author: Kim, K.
Paper Title Page
WEPAB087 Observation of Undulator Radiation Generated by a Single Electron Circulating in a Storage Ring and Possible Applications 2790
 
  • I. Lobach
    University of Chicago, Chicago, Illinois, USA
  • A. Halavanau, Z. Huang
    SLAC, Menlo Park, California, USA
  • K. Kim
    ANL, Lemont, Illinois, USA
  • S. Nagaitsev, A.L. Romanov, G. Stancari, A. Valishev
    Fermilab, Batavia, Illinois, USA
 
  An experimental study into the undulator radiation, generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The individual photons were detected by a Single Photon Avalanche Diode (SPAD) at an average rate of 1 detection per 300 revolutions in the ring. The detection events were continuously recorded by a picosecond event timer for as long as 1 minute at a time. The collected data were used to test if there is any deviation from the classically predicted Poissonian photostatistics. It was motivated by the observation * of sub-Poissonian statistics in a similar experiment. The observation * could be an instrumentation effect related to low detection efficiency and long detector dead time. In our experiment, the detector (SPAD) has a much higher efficiency (65%) and a much lower dead time. In addition, we show that the collected data (recorded detection times) can be used to study the synchrotron motion of a single electron and infer some parameters of the ring. For example, by comparing the results of simulation and measurement for the synchrotron motion we were able to estimate the magnitude of the RF phase jitter.
* Teng Chen and John M. J. Madey, Phys. Rev. Lett. 86, 5906, June 2001
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB087  
About • paper received ※ 17 May 2021       paper accepted ※ 24 June 2021       issue date ※ 16 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB088 Transverse Beam Emittance Measurement by Undulator Radiation Power Noise 2794
 
  • I. Lobach
    University of Chicago, Chicago, Illinois, USA
  • A. Halavanau, Z. Huang
    SLAC, Menlo Park, California, USA
  • K. Kim
    ANL, Lemont, Illinois, USA
  • V.A. Lebedev, S. Nagaitsev, A.L. Romanov, G. Stancari, A. Valishev
    Fermilab, Batavia, Illinois, USA
 
  Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB088  
About • paper received ※ 17 May 2021       paper accepted ※ 24 June 2021       issue date ※ 12 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)