Paper | Title | Page |
---|---|---|
MOPAB279 | Non-Invasive Beam Profile Monitoring for the HL-LHC Hollow Electron Lens | 884 |
|
||
Funding: This work was supported by the HL-LHC-UK phase II project funded by STFC under Grant Ref: ST/T001925/1 and the STFC Cockcroft core grant No. ST/G008248/1. A Hollow Electron Lens (HEL) is currently under development for the High-Luminosity upgrade of the Large Hadron Collider (HL-LHC). In this device, a hollow electron beam co-propagates with a central proton beam and provides active halo control in the LHC. To ensure the concentricity of the two beams, a non-invasive diagnostic instrument is currently being commissioned. This instrument is a compact version of an existing prototype that leverages beam induced fluorescence with supersonic gas curtain technology. This contribution includes the design features of this version of the monitor, recent progress, and future plans for tests at the Cockcroft Institute and the electron lens test stand at CERN. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB279 | |
About • | paper received ※ 18 May 2021 paper accepted ※ 15 June 2021 issue date ※ 02 September 2021 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPAB392 | Conceptual Design of the Vacuum System for the Future Circular Collider FCC-ee Main Rings | 2438 |
|
||
The Future Circular Collider study program comprises several machine concepts for the future of high-energy particle physics. Among them there is a twin-ring e−e+ collider capable to run at beam energies between 45.6 and 182.5 GeV, i.e. the energies corresponding to the resonances of the Z, W, H bosons and the top quark. The conceptual design of the two 100-km rings has advanced to what is believed to be a working solution, i.e. capability to deal with low-energy (45.6 GeV) high-current (1390 mA) version as well as the high-energy (182.5 GeV) low-current (5.4 mA) one, with intermediate energy and current steps for the other 2 resonances. The limit for all of the versions is given by the 50 MW/beam allotted to the synchrotron radiation (SR) losses. The paper will outline the main beam/machine parameters, the vacuum requirements, and the choices made concerning the vacuum chamber geometry, material, surface treatments, pumping system, and the related pressure profiles. The location of lumped SR photon absorbers for the generic arc cell has been determined. An outline of the studies needed and envisaged for the near future will also be given. | ||
![]() |
Poster TUPAB392 [3.036 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB392 | |
About • | paper received ※ 19 May 2021 paper accepted ※ 31 May 2021 issue date ※ 25 August 2021 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPAB029 | Challenges for the Interaction Region Design of the Future Circular Collider FCC-ee | 2668 |
|
||
Funding: This work was partially supported by the EC HORIZON 2020 project FCC-IS, grant agreement n.951754, and by the U. S. Department of Energy, Office of Science, under Contract No. DE-AC02-76SF-00515. The FCC-ee is a proposed future high-energy, high-intensity and high precision lepton collider. Here, we present the latest developments for the FCC-ee interaction regions, which shall ensure optimum conditions for the particle physics experiments. We discuss measures of background reduction and a revised interaction region layout including a low impedance compact beam chamber design. We also discuss the possible impact of the radiation generated in the interaction region including beamstrahlung. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB029 | |
About • | paper received ※ 11 May 2021 paper accepted ※ 23 June 2021 issue date ※ 30 August 2021 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |