Paper |
Title |
Page |
MOPAB281 |
Research on Resolution Evaluation of Stripline BPM at SXFEL-UF |
892 |
|
- B. Gao, J. Chen, Y.B. Leng
SSRF, Shanghai, People’s Republic of China
|
|
|
48 stripline BPMs are installed in the injection section and linear acceleration section of Shanghai X-ray Free Electron Laser (SXFEL) for electron beam position measurement. These two sections require resolution of 20 µm@100pC. Resolution evaluation is an important step in BPM installation and commissioning. This paper presents BPM resolution evaluation methods based on correlation analysis. Experimental methods, data processing and result analysis will be discussed
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB281
|
|
About • |
paper received ※ 19 May 2021 paper accepted ※ 27 May 2021 issue date ※ 02 September 2021 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,