Author: Chen, J.
Paper Title Page
MOPAB281 Research on Resolution Evaluation of Stripline BPM at SXFEL-UF 892
 
  • B. Gao, J. Chen, Y.B. Leng
    SSRF, Shanghai, People’s Republic of China
 
  48 stripline BPMs are installed in the injection section and linear acceleration section of Shanghai X-ray Free Electron Laser (SXFEL) for electron beam position measurement. These two sections require resolution of 20 µm@100pC. Resolution evaluation is an important step in BPM installation and commissioning. This paper presents BPM resolution evaluation methods based on correlation analysis. Experimental methods, data processing and result analysis will be discussed  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB281  
About • paper received ※ 19 May 2021       paper accepted ※ 27 May 2021       issue date ※ 02 September 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
FRXC06 Development of the Prototype of the Cavity BPM System for SHINE 4552
 
  • J. Chen, Y.B. Leng, R.X. Yuan
    SSRF, Shanghai, People’s Republic of China
  • S.S. Cao
    SINAP, Shanghai, People’s Republic of China
  • L.W. Lai
    SARI-CAS, Pudong, Shanghai, People’s Republic of China
 
  The Shanghai high repetition rate XFEL and extreme light facility (SHINE) under construction is designed as one of the most advanced FEL facilities in the world, which will produce coherent x-rays with wavelengths from 0.05 to 3 nm and maximum repetition rate of 1MHz. In order to achieve precise, stable alignment of the electron and photo beams in the undulator, the prototype of the cavity beam position monitors (CBPM) including C-band and X-band have been designed and fabricated for the SHINE. And the requirement of the transverse position resolution is better than 200 nm for a single bunch of 100 pC at the dynamic range of ±100 µm. In this paper, we present the design of the cavity with high loaded Q and the RF front-end with low noise-figure, adjustable gain, single-stage down-conversion and phase-locked with reference clock, and also described the structure and specifications of the home-made data acquisition (DAQ) system. The construction of the experiment platform and preliminary measurement result with beam at Shanghai Soft X-ray FEL facility (SXFEL) will be addressed as well.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-FRXC06  
About • paper received ※ 20 May 2021       paper accepted ※ 06 July 2021       issue date ※ 17 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)