Author: Butenko, A.V.
Paper Title Page
MOPAB192 LILac Energy Upgrade to 13 MeV 651
 
  • B. Koubek, S. Altürk, M. Busch, H. Höltermann, J.D. Kaiser, H. Podlech, U. Ratzinger, M. Schuett, M. Schwarz, W. Schweizer, D. Strehl, R. Tiede, C. Trageser
    BEVATECH, Frankfurt, Germany
  • A. Brunzel, P. Nonn, H. Schlarb
    DESY, Hamburg, Germany
  • A.V. Butenko, D.E. Donets, B.V. Golovenskiy, A. Govorov, K.A. Levterov, D.A. Lyuosev, A.A. Martynov, V.A. Monchinsky, D.O. Ponkin, K.V. Shevchenko, I.V. Shirikov, E. Syresin
    JINR, Dubna, Moscow Region, Russia
 
  In the frame of the NICA (Nuclotron-based Ion Collider fAcility) ion collider upgrade a new light ion LINAC for protons and ions will be built in collaboration between JINR and BEVATECH GmbH. While ions with a mass-to-charge ratio up to 3 will be fed into the NUCLOTRON ring with an energy of 7 MeV/u, protons are supposed to be accelerated up to an energy of 13 MeV using a third IH structure. This energy upgrade comprises a third IH structure, a dual-use Debuncher cavity as well as an extension of the LLRF control system built on MicroTCA technology.  
poster icon Poster MOPAB192 [4.914 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB192  
About • paper received ※ 11 May 2021       paper accepted ※ 31 May 2021       issue date ※ 20 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB300 Description of the Beam Diagnostics Systems for the SOCIT, SODIT and SODIB Applied Research Stations Based on the NICA Accelerator Complex 946
 
  • A. Slivin, A. Agapov, A.A. Baldin, A.V. Butenko, G.A. Filatov, K.N. Shipulin, E. Syresin, G.N. Timoshenko, A. Tuzikov
    JINR, Dubna, Moscow Region, Russia
  • D.V. Bobrovskiy, A.I. Chumakov, S. Soloviev
    MEPhI, Moscow, Russia
  • I.L. Glebov, V.A. Luzanov
    GIRO-PROM, Dubna, Moscow Region, Russia
  • A.S. Kubankin
    BelSU, Belgorod, Russia
  • T. Kulevoy, Y.E. Titarenko
    ITEP, Moscow, Russia
 
  Within the framework of the NICA project an Innovation Block is being constructed. It includes an applied research station for microchips with a package for Single Event Effects (SEE) testing (energy range of 150-500 MeV/n, the SODIT station), an applied research station for testing of decapsulated microchips (ion energy up to 3,2 MeV/n, the SOCIT station), and an applied research station for space radiobiological research and modelling of influence of heavy charged particles on cognitive functions of the brain of small laboratory animals and primates (energy range 500-1000 MeV/n, the SODIB station). The systems for diagnostics and control of the beam characteristics during the certification and adjustment as well as the systems for online diagnostics and control of the beam characteristics of the SOCIT, SODIT and SODIB applied research stations are described.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB300  
About • paper received ※ 19 May 2021       paper accepted ※ 27 May 2021       issue date ※ 23 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB301 A Concept for Reconstruction of the Capsulated Microchip Structure Using Its Interaction with High-Energy Ion Beams of the NICA Accelerator Complex 949
 
  • A. Slivin, A.V. Butenko, G.A. Filatov, E. Syresin, A. Tuzikov, A. Zhemchugov
    JINR, Dubna, Moscow Region, Russia
 
  Within the framework of the NICA project an applied research station for irradiation by long-range ions (SODIT) is being constructed for testing radiation hardness of semiconductor micro- and nanoelectronics products in the energy range of 150-350 MeV/n. Calculations for the interaction of high-energy gold ions with the microchip and strip detector structures are performed using the GEANT4 simulation toolkit. A concept was developed for reconstruction of the capsulated microchip structure in terms of depth and in terms of cross-section using interaction with high-energy ions at the technical station for irradiation by long-range ions. The possibility of localizing the radiation-vulnerable area of the microchip is evaluated.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB301  
About • paper received ※ 19 May 2021       paper accepted ※ 20 May 2021       issue date ※ 17 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB363 Design, Characteristics and Dynamic Properties of Mobile Plunger-based Frequency Tuning System for Coaxial Half Wave Resonators 1129
 
  • D. Bychanok, S. Huseu, S.A. Maksimenko, A.E. Sukhotski
    INP BSU, Minsk, Belarus
  • A.V. Butenko, E. Syresin
    JINR, Dubna, Moscow Region, Russia
  • M. Gusarova, M.V. Lalayan, S.M. Polozov
    MEPhI, Moscow, Russia
  • V.S. Petrakovsky, A.I. Pokrovsky, A. Shvedov, S.V. Yurevich
    Physical-Technical Institute of the National Academy of Sciences of Belarus, Minsk, Belarus
  • Y. Tamashevich
    HZB, Berlin, Germany
 
  The practical realization of a prototype of the frequency tuning system (FTS) for coaxial half-wave cavities (HWR) for the Nuclotron-based Ion Collider fAcility (NICA) injector is presented. The impact of FTS on electromagnetic parameters of copper HWR prototype is experimentally studied and discussed. The most important parameters like tuning range, tuning sensitivity, the dependence of the resonant frequency on the position of the plungers are estimated. The effective operation algorithms of the proposed FTS are discussed and analyzed. The dynamic characteristics of FTS are investigated and showed the ability to adjust the frequency with an accuracy of about 70 Hz.  
poster icon Poster MOPAB363 [3.597 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB363  
About • paper received ※ 18 May 2021       paper accepted ※ 09 June 2021       issue date ※ 11 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPAB415 Irradiation Methods and Infrastructure Concepts of New Beam Lines for NICA Applied Research 2498
 
  • G.A. Filatov, A. Agapov, A.V. Butenko, K.N. Shipulin, A. Slivin, E. Syresin, A. Tuzikov, A.S. Vorozhtsov
    JINR, Dubna, Moscow Region, Russia
  • S. Antoine, W. Beeckman, X.G. Duveau, J. Guerra-Phillips, P.J. Jehanno
    SIGMAPHI S.A., Vannes, France
 
  Nowadays space exploration has faced the issue of radiation risk to microelectronics and biological objects. The new beamlines and irradiation stations of the Nuclotron-based Ion Collider fAcility (NICA) at JINR are currently under construction to study this issue. The beamline parameters, different methods for homogeneous irradiation of targets such as scanning, and beam profile shaping by octupole magnets are discussed. A short description of the building infrastructure, magnet elements, and detectors for these beamlines is also given.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-TUPAB415  
About • paper received ※ 11 May 2021       paper accepted ※ 02 June 2021       issue date ※ 13 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPAB176 Acceleration of He+ Beams for Injection Into NICA Booster During its First Run 3016
 
  • K.A. Levterov, V.P. Akimov, D.S. Letkin, D.O. Leushin, V.V. Mialkovskiy
    JINR/VBLHEP, Dubna, Moscow region, Russia
  • A.M. Bazanov, A.V. Butenko, D.E. Donets, D. Egorov, A.R. Galimov, B.V. Golovenskiy, A. Govorov, V.V. Kobets, A.D. Kovalenko, D.A. Lyuosev, A.A. Martynov, V.A. Monchinsky, D.O. Ponkin, I.V. Shirikov, A.O. Sidorin, E. Syresin, G.V. Trubnikov, A. Tuzikov
    JINR, Dubna, Moscow Region, Russia
  • H. Höltermann, H. Podlech
    BEVATECH, Frankfurt, Germany
  • U. Ratzinger, A. Schempp
    IAP, Frankfurt am Main, Germany
 
  Heavy Ion Linear Accelerator (HILAC) is designed to accelerate the heavy ions with ratio A/Z<=6.25 produced by ESIS ion source up to the 3.2 MeV for the injection into superconducting synchrotron (SC) Booster. HILAC was commissioned in 2018 using the carbon beams from Laser Ion Source (LIS). The project output energy was verified. Transmission could be estimated only for DTL structure because of the presence at the RFQ input the mixture of ions with different charge states extracted from laser-plasma. To estimate transmission through the whole linac the ion source producing the only species He+ was designed. The beams of He+ ions were used for the first run of SC Booster. The design of the helium ion source and results of the He+ beam acceleration and injection are described.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB176  
About • paper received ※ 19 May 2021       paper accepted ※ 11 June 2021       issue date ※ 22 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
MOPAB025 First Experiments with Accelerated Ion Beams in the Booster of NICA Accelerator Complex 123
 
  • A.V. Butenko, V. Andreev, A.M. Bazanov, O.I. Brovko, D.E. Donets, A.V. Eliseev, I.V. Gorelyshev, A.V. Konstantinov, S.A. Kostromin, O.S. Kozlov, K.A. Levterov, A. Nesterov, A.V. Philippov, D.O. Ponkin, G.S. Sedykh, I.V. Shirikov, A.O. Sidorin, E. Syresin, A. Tuzikov, V. Volkov
    JINR/VBLHEP, Moscow, Russia
  • N.N. Agapov, A.V. Alfeev, A.A. Baldin, A.A. Fateev, A.R. Galimov, B.V. Golovenskiy, E.V. Gorbachev, A. Govorov, E.V. Ivanov, V. Karpinsky, V.D. Kekelidze, H.G. Khodzhibagiyan, A. Kirichenko, A.G. Kobets, S.A. Korovkin, V. Kosachev, A.D. Kovalenko, G. Kunchenko, I.N. Meshkov, V.A. Mikhailov, V.A. Monchinsky, D. Nikiforov, R.V. Pivin, S. Romanov, A.A. Shurygin, A.I. Sidorov, A.N. Svidetelev, G.V. Trubnikov, B. Vasilishin
    JINR, Dubna, Moscow Region, Russia
  • G.A. Fatkin
    Cosylab Siberia, Novosibirsk, Russia
 
  The NICA accelerator complex in JINR consist of two linear injector chains, a 578 MeV/u superconducting (SC) Booster synchrotron, the existing SC synchrotron Nuclotron, and a new SC collider that has two storage rings. The construction of the facility is based on the Nuclotron technology of SC magnets with an iron yoke and hollow SC cable. Assembly of the Booster synchrotron was finished in autumn of 2020 and first machine Run and experiments with ion beams were successfully done in December 2020. The results of this Run are discussed in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB025  
About • paper received ※ 16 May 2021       paper accepted ※ 07 September 2021       issue date ※ 15 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)