Author: Brunner, K.
Paper Title Page
MOPAB364 Shielded Pair Method for Cylindrical Surface Resistance Measurement at Cryogenic Temperature 1132
 
  • K. Brunner, S. Calatroni, F. Caspers
    CERN, Geneva, Switzerland
  • D. Barna
    Wigner Research Centre for Physics, Institute for Particle and Nuclear Physics, Budapest, Hungary
 
  The shielded pair resonator method was already used in the past at CERN to measure the surface resistivity of the LHC beam screen both at room temperature and cryogenic temperature. We have refined and adapted the measurement to be able to measure other types of beam screens and also to operate in a strong dipolar magnetic field. This is necessary for testing the properties of HTS coated beam screens or the possible effects of coatings and surface treatments for e-cloud suppression. Several calibration runs were done at cryogenic temperatures (4.2 K) measuring the surface resistivity of a copper pipe to identify the precision, stability and reproducibility achievable using this method. This work describes the challenges of the measurement and ways to mitigate them.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-MOPAB364  
About • paper received ※ 17 May 2021       paper accepted ※ 22 June 2021       issue date ※ 12 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)