Author: Bernardini, J.
Paper Title Page
THPAB343 Test Results of the Prototype SSR1 Cryomodule for PIP-II at Fermilab 4461
 
  • D. Passarelli, J. Bernardini, C. Boffo, B.M. Hanna, S. Kazakov, T.N. Khabiboulline, A. Lunin, J.P. Ozelis, M. Parise, Y.M. Pischalnikov, V. Roger, B. Squires, A.I. Sukhanov, G. Wu, V.P. Yakovlev, S. Zorzetti
    Fermilab, Batavia, Illinois, USA
  • C. Contreras-Martinez
    FRIB, East Lansing, Michigan, USA
 
  Funding: Work supported by Fermi Research Alliance, LLC under Contract No. DEAC02- 07CH11359 with the United States Department of Energy
A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses has been successfully assembled and cold tested in the framework of PIP-II project at Fermilab. The performance of cavities and focusing lenses along with test results of other cryomodule’s key parameters are presented in this contribution.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-THPAB343  
About • paper received ※ 20 May 2021       paper accepted ※ 08 August 2021       issue date ※ 28 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPAB352 Computer Vision Techniques Used to Monitor the Alignment of Cavities and Solenoids in the PIP-II Prototype SSR1 Cryomodule 4485
 
  • S. Zorzetti, J. Bernardini, D. Passarelli
    Fermilab, Batavia, Illinois, USA
 
  The alignment of the SRF PIP-II string components is studied as the acceptable beam deflection, offset and defocusing, which may otherwise cause beam loss. Simulations and measurements established that the maximum deviation of the beam pipe from the reference orbit should not exceed a small fraction of the beam aperture. To observe the translations and rotations of each single component within the cryomodule, optical instruments (H-BCAM) surveying highly reflective targets, installed in the internal assembly of the module were used. The alignment monitoring concept for the PIP II SSR1 prototype cryomodule, along with relevant measurements of the components’ position monitoring during coldmass cooldown is presented in this contribution. This development paves the way to new computer vision applications in the field of cryomodule assemblies in cleanroom environment, in which robotically-assisted operations have the potential to dramatically reduce the risk of chemical and particulate contamination.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-THPAB352  
About • paper received ※ 19 May 2021       paper accepted ※ 02 August 2021       issue date ※ 31 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)