Author: Benedetti, G.
Paper Title Page
WEPAB074 A Distributed Sextupoles Lattice for the ALBA Low Emittance Upgrade 2762
 
  • G. Benedetti, M. Carlà, U. Iriso, Z. Martí, F. Pérez
    ALBA-CELLS Synchrotron, Cerdanyola del Vallès, Spain
 
  The first lattice studied in 2019 for the ALBA upgrade was a 7BA lattice with two dispersion bumps, for localised chromatic correction. That lattice had limited dynamic aperture and momentum acceptance. In 2020 we started to explore a different approach to find an MBA lattice with distributed chromatic correction that meets the same emittance goal with larger dynamic aperture and momentum acceptance. The choice of the number of bendings per cell, as well as the tuning of the magnet gradients, is carried out by developing a light weight solver that performs both the emittance and chromaticity optimisation of the arcs and the matching of the linear optics in the straight sections. We present the status of the storage ring upgrade studies, the performance of the new developed lattice, together with the issues related with the injection scheme.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB074  
About • paper received ※ 19 May 2021       paper accepted ※ 16 June 2021       issue date ※ 22 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THXB05 Inverse Orbit Response Matrix Measurements: A Possible On-Line Tool for Optics Control in Storage Rings 3724
 
  • Z. Martí, G. Benedetti, U. Iriso, E. Morales
    ALBA-CELLS Synchrotron, Cerdanyola del Vallès, Spain
 
  We propose a novel technique to measure the linear optics in storage rings based on the acquisition of the inverse orbit response matrix (iORM). The iORM consists in the orbit correctors magnets (OCM) strength changes needed to produce a local orbit variation in each beam position monitor (BPM). This measurement can be implemented by introducing sequentially small changes in the BPM offsets and logging the OCM setting variations when the orbit correction is running. Very high precision and accuracy in the OCM set-points is required which poses a considerable challenge. Since the orbit feedback (FOFB) is kept running, the iORM could potentially be acquired in parallel to users storage ring operation. Since the iORM is very linear and local, optics perturbations could be easily diagnosed online. This paper introduces the iORM measurement concept and presents the progress of these studies at ALBA, where the implementation of this technique is limited by hysteresis effects in the OCM and the FOFB performance.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-THXB05  
About • paper received ※ 19 May 2021       paper accepted ※ 29 July 2021       issue date ※ 12 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)