Author: Angot, J.
Paper Title Page
WEPAB396 First Measurements on Multipactor Study 3633
 
  • Y. Gómez Martínez, J. Angot, M.A. Baylac, T. Cabanel, P.-O. Dumont, N. Emeriaud, O. Zimmermann
    LPSC, Grenoble Cedex, France
  • D. Longuevergne
    FLUO, Orsay, France
  • G. Sattonnay
    Université Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France
 
  Multipactor (MP) is an undesired phenomenon of resonant electron build up encountered on particle accelerators. It can induce anomalous thermal losses, higher than the Joule losses, inducing a decrease of the superconducting cavities quality factor, it can even lead to a cavity quench. On couplers, it can produce irreversible damages or generate a breakdown of their vacuum window. Multipactor may lead to Electron Cloud build up as well. The accelerator group at LPSC has developed a test bench dedicated to the multipactor studies. This paper presents the experimental set-up and its first measurements.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2021-WEPAB396  
About • paper received ※ 18 May 2021       paper accepted ※ 14 July 2021       issue date ※ 17 August 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)