RIS citation export for TUPAB324: Real-Time Radiation Monitoring System with Interlock Protection Mechanism in Taiwan Photon Source

TY  - CONF
AU  - Lin, Y.C.
AU  - Chen, A.Y.
AU  - Chen, C.-R.
AU  - Huang, S.J.
AU  - Kao, S.P.
AU  - Lin, S.Y.
AU  - Liu, J.C.
AU  - Wen, P.J.
ED  - Liu, Lin
ED  - Byrd, John M.
ED  - Neuenschwander, Regis T.
ED  - Picoreti, Renan
ED  - Schaa, Volker R. W.
TI  - Real-Time Radiation Monitoring System with Interlock Protection Mechanism in Taiwan Photon Source
J2  - Proc. of IPAC2021, Campinas, SP, Brazil, 24-28 May 2021
CY  - Campinas, SP, Brazil
T2  - International Particle Accelerator Conference
T3  - 12
LA  - english
AB  - To ensure radiation safety for personnel working in the facility, the Radiation and Operation Safety Division has installed a real-time radiation monitoring system in the working area to monitor gamma rays and neutrons, for which the annual dosage limit is designed to be less than 1 mSv/year. Considering 2000 working hours for users and staff members, we have derived a control dose rate limit 2 µSv/4h for interlock protection. If the accumulated radiation dose monitored with the system exceeds 2µSv within a 4-h counting interval, the radiation monitoring station sends a signal to the interlock system to stop injection until the next counting period interval. This paper introduces the radiation monitoring system and its related design information in Taiwan Photon Source.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 2256
EP  - 2259
KW  - radiation
KW  - monitoring
KW  - neutron
KW  - synchrotron
KW  - electron
DA  - 2021/08
PY  - 2021
SN  - 2673-5490
SN  - 978-3-95450-214-1
DO  - doi:10.18429/JACoW-IPAC2021-TUPAB324
UR  - https://jacow.org/ipac2021/papers/tupab324.pdf
ER  -