JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


BiBTeX citation export for TUPAB065: Solaris Storage Ring Performance After 6 Years of Operation

@inproceedings{wawrzyniak:ipac2021-tupab065,
  author       = {A.I. Wawrzyniak and A. Curcio and K. Gula and M.A. Knafel and G.W. Kowalski and A.M. Marendziak and R. Panaś and M. Waniczek and M. Wiśniowski},
% author       = {A.I. Wawrzyniak and A. Curcio and K. Gula and M.A. Knafel and G.W. Kowalski and A.M. Marendziak and others},
% author       = {A.I. Wawrzyniak and others},
  title        = {{Solaris Storage Ring Performance After 6 Years of Operation}},
  booktitle    = {Proc. IPAC'21},
  pages        = {1515--1517},
  eid          = {TUPAB065},
  language     = {english},
  keywords     = {storage-ring, operation, MMI, synchrotron, vacuum},
  venue        = {Campinas, SP, Brazil},
  series       = {International Particle Accelerator Conference},
  number       = {12},
  publisher    = {JACoW Publishing, Geneva, Switzerland},
  month        = {08},
  year         = {2021},
  issn         = {2673-5490},
  isbn         = {978-3-95450-214-1},
  doi          = {10.18429/JACoW-IPAC2021-TUPAB065},
  url          = {https://jacow.org/ipac2021/papers/tupab065.pdf},
  note         = {https://doi.org/10.18429/JACoW-IPAC2021-TUPAB065},
  abstract     = {{Solaris is a third generation light source operating since 2015 in Kraków, Poland. Between 2015 and 2018 the synchrotron as well as two beamlines were commissioned. During commissioning phases, the good performance of Solaris storage ring has been reached. The beam optics was brought close to the design one. Since October 2018 Solaris storage ring is in the user operation mode. Moreover, two other beamlines with the elliptically polarized undulators used as source were installed and are under commissioning now. In 2020 the total beam availability of 93% was reached with the average circulating current of 400 mA and the total lifetime of 15 h. Over last two years few improvements of the storage ring were done to optimize the storage ring performance. The Landau cavities were tuned to improve the Touschek lifetime and suppress the instabilities. Two diagnostics beamlines were installed and commissioned allowing for the beam sizes in three planes and emittance measurements. The storage ring optics was fine-tuned to increase the dynamic aperture.}},
}