Author: Zhang, S.
Paper Title Page
MOPRB110 Simulation Study of the Emittance Measurements in Magnetized Electron Beam 822
 
  • S.A.K. Wijethunga, J.R. Delayen, G.A. Krafft
    ODU, Norfolk, Virginia, USA
  • J.F. Benesch, F.E. Hannon, G.A. Krafft, M.A. Mamun, G.G. Palacios Serrano, M. Poelker, R. Suleiman, S. Zhang
    JLab, Newport News, Virginia, USA
 
  Funding: This work is supported by the Department of Energy, Laboratory Directed Research and Development funding, under contract DE-AC05-06OR23177
Electron cooling of the ion beam is key to obtaining the required high luminosity of proposed electron-ion colliders. For the Jefferson Lab Electron Ion Collider, the expected luminosity of 1034 〖 cm〗-2 s-1 will be achieved through so-called ’magnetized electron cooling’, where the cooling process occurs inside a solenoid field, which will be part of the collider ring and facilitated using a circulator ring and Energy Recovery Linac (ERL). As an initial step, we generated magnetized electron beam using a new compact DC high voltage photogun biased at -300 kV employing an alkali-antimonide photocathode. This contribution presents the characterization of the magnetized electron beam (emittance variations with the magnetic field strength for different laser spot sizes) and a comparison to GPT simulations.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-MOPRB110  
About • paper received ※ 15 May 2019       paper accepted ※ 20 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPTS105 High Current High Charge Magnetized and Bunched Electron Beam from a DC Photogun for JLEIC Cooler 2167
 
  • S. Zhang, P.A. Adderley, J.F. Benesch, D.B. Bullard, J.M. Grames, J. Guo, F.E. Hannon, J. Hansknecht, C. Hernandez-Garcia, R. Kazimi, G.A. Krafft, M.A. Mamun, M. Poelker, R. Suleiman, M.G. Tiefenback, Y.W. Wang
    JLab, Newport News, Virginia, USA
  • J.R. Delayen, G.A. Krafft, Y.W. Wang, S.A.K. Wijethunga
    ODU, Norfolk, Virginia, USA
 
  Funding: This project was supported by the U.S. DOE Basic Energy Sciences under contract No. DE-AC05-060R23177. Additional support comes from Laboratory Directed Research and Development program.
A high current, high charge magnetized electron beamline that has been under development for fast and efficient cooling of ion beams for the proposed Jefferson Lab Electron Ion Collider (JLEIC). In this paper, we present the latest progress over the past year that include the generation of picosecond magnetized beam bunches at average currents up to 28 mA with exceptionally long photocathode lifetime, and the demonstrations of magnetized beam with high bunch charge up to 700 pC at 10s of kHz repetition rates. Detailed studies on a stable drive laser system, long lifetime photocathode, beam magnetization effect, beam diagnostics, and a comparison between experiment and simulations will also be reported. These accomplishes marked an important step towards the essential feasibility for the JLEIC cooler design using magnetized beams.
(To be inserted)
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPTS105  
About • paper received ※ 15 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPGW044 Highly Stable Linearly Polarized Arbitrary Temporal Shaping of Picosecond Laser Pulses 3682
SUSPFO062   use link to see paper's listing under its alternate paper code  
 
  • F. Liu, S. Huang, K.X. Liu
    PKU, Beijing, People’s Republic of China
  • S. Zhang
    JLab, Newport News, Virginia, USA
 
  This paper reports the study and demonstration of a new variable temporal shaping method capable of generating linearly polarized picosecond laser pulses with arbitrary predefined shapes, which are highly desired by various applications including low emittance high brightness electron bunch generation in photocathode guns. It is found that both high transmittance and high stability of the shaped pulses can be achieved simultaneously when crystals are set at specific phase delay through the fine control of the crystal temperature. Such variable temporal shaping technique may lead to new opportunities for many potential applications over a wide range of laser wavelengths, pulse repetition rates, time structures and power levels, etc. In addition, a new double-pass variable shaping method is also proposed and could significantly simplify the shaper structure and reduce the cost.
*liufangming@pku.edu.cn
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPGW044  
About • paper received ※ 13 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)