Paper |
Title |
Page |
TUPRB081 |
Beam Motion and Photon Flux Dips during Injection at the Taiwan Photon Source |
1848 |
|
- C.H. Huang, H.-P. Chang, C.H. Chen, Y.-S. Cheng, P.C. Chiu, C.-S. Fann, K.T. Hsu, K.H. Hu, C.Y. Liao, Y.-C. Liu, C.Y. Wu
NSRRC, Hsinchu, Taiwan
|
|
|
The Taiwan photon source (TPS) is a 3 GeV synchrotron light source now in routine operation at the NSRRC. At the beginning of beam commissioning, significant photon flux dips could be observed at injection due to a blow-up of the beam size. To eliminate this transient effect, all four kickers were rematched. The leakage field was shielded and the induced current loops at vacuum chambers in the injection area were also eliminated. These efforts reduced the horizontal betatron oscillations and orbit distortions to around one-tenth. In order to decrease the recovery time of photon dips during injection, the operational chromaticity was reduced to improve incoherent effects. After all those improvements, the photon flux dips during injection dropped to 30 % and the recovery time to less than 1 msec.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPRB081
|
|
About • |
paper received ※ 17 April 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPTS070 |
Diagnostic Tool For CompactPCI Crates |
4275 |
|
- H.Z. Chen, C.H. Chen, Y.-S. Cheng, K.T. Hsu, K.H. Hu, C.Y. Liao, C.Y. Wu
NSRRC, Hsinchu, Taiwan
|
|
|
On the control system hardware platform for the Taiwan Photon Source (TPS) more than half use CompactPCI crates. If a crate malfunctions, the internal crate card will not operate properly affecting accelerator operation. If the crate, however, could provide instant remote operational information, an opportunity exists to maintain or replace it in advance. Therefore, a diagnostic tool was developed to analyse and diagnose the condition of the crates. When abnormal operations occur, an alarm can be issued for early inspection and maintenance. This way it is possible to prevent the EPICS IOC from crashing by CompactPCI crates, which improves the reliability of accelerator operation. A detailed system architecture, implementation and progress will be discussed in this report.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPTS070
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|