Author: Wang, X.Q.
Paper Title Page
TUPTS046 Commissioning of a Compact THz Source Based on FEL 2030
 
  • Y.J. Pei, G. Feng, X.Y. He, Y. Hong, D. Jia, P. Lu, S. Lu, L. Shang, B.G. Sun, Zh.X. Tang, W. Wang, X.Q. Wang, W. Wei
    USTC/NSRL, Hefei, Anhui, People’s Republic of China
  • L. Cao, Q.S. Chen, Q. Fu, T. Hu, P. Tan, Y.Q. Xiong
    HUST, Wuhan, People’s Republic of China
  • G. Huang
    IMP/CAS, Lanzhou, People’s Republic of China
  • L.G. Shen, F. Zhang
    USTC/PMPI, Hefei, Anhui, People’s Republic of China
 
  The layout of the THz source based on FEL was de-scribed in this paper. The THz source was based on a FEL which was composed of a compact 8-14MeV LINAC, undulator, optical resonance, THz wave measurement system and so on. The facility was designed in 2013 and the typical running parameter got in 2017 were as the following: energy is of 12.7MeV, energy spread is of 0.3%, macro-pulse is of 4 μs, pulse length of micro-pulse is of 6ps, emittance is of 24 mm.mrad. After that the ma-chine was commissioning for production THz radiation. In November 2018, the THz wave was test and got THz wave signal, the spectrum was also got. This year, we plan to measure the output power of the THz source.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPTS046  
About • paper received ※ 15 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPTS048 Design of Longitudinal Gradient Bending Magnet of HALS 4215
 
  • B. Zhang, C. Chen, Z.L. Ren, X.Q. Wang, H. Xu
    USTC/NSRL, Hefei, Anhui, People’s Republic of China
 
  Hefei Advanced Light Source (HALS) is a diffraction limited light source, which was proposed and expected to be built in the next few years by National Synchrotron Radiation Laboratory (NSRL) of China. Just like other new light sources, longitudinal gradient bending magnet (LGB) will be adopted to suppress the beam emittance. The magnet consists of 7 modules with different magnet-ic field. Each module has yoke and poles with the same size but different amount of permanent magnet to gener-ate field gradient. FeNi alloy is used to shunt magnetic flux and thus improve the temperature stability. Correc-tor coil or movable wedge can be used to adjust the field. Impact of magnetization direction error of permanent magnet block and parallelism error of poles on multi-poles is also evaluated.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPTS048  
About • paper received ※ 14 May 2019       paper accepted ※ 23 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)