Author: Wang, Q.
Paper Title Page
WEPGW044 Study on the Influence of Beam Transverse Position on the Cavity Bunch Length Measurement 2578
 
  • Q. Wang, S.M. Jiang, Q. Luo, B.G. Sun
    USTC/NSRL, Hefei, Anhui, People’s Republic of China
 
  Funding: Work supported by National Key R&D Program of China (Grant No. 2016YFA0401900 and No. 2016YFA0401903) and The National Natural Science Foundation of China (Grant No. U1832169 and No. 11575181).
Monopole modes in the resonant cavity are wildly used to obtain the beam current and the bunch length, while dipole modes are used to measure the beam transverse position. It is generally recognized that the monopole modes are independent of the beam transverse offset. In this paper, the influence of beam transverse offset on the bunch length measurement using monopole modes is analyzed. The simulation results show that the relative error of the bunch length measurement is less than 1 % when the beam offset is within 1 mm.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW044  
About • paper received ※ 25 April 2019       paper accepted ※ 20 May 2019       issue date ※ 21 June 2019  