Author: Villari, A.C.C.
Paper Title Page
WEPGW112 Energy Calibration of the Rea3 Accelerator by Time-of-Flight Technique* 2760
 
  • A.C.C. Villari, D.B. Crisp, A. Lapierre, S. Nash, T. Summers, Q. Zhao
    NSCL, East Lansing, Michigan, USA
 
  Funding: * This material is based upon work supported by the National Science Foundation under Grant No. PHY15-65546.
We report on a simple method to perform an absolute calibration of the magnetic beam analyser of the reaccelerator ReA3 at the National Superconducting Cyclotron Laboratory. The method is based on the time of flight between two beam stoppers 7.65 m apart. Based on two independent time-of-flight measurements at three different beam energies, the beam analyser magnet is calibrated with an accuracy of 0.12 %, corresponding to a beam energy accuracy of 0.24 %.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW112  
About • paper received ※ 25 April 2019       paper accepted ※ 28 May 2019       issue date ※ 21 June 2019  