Paper |
Title |
Page |
TUPMP017 |
Design of Scanning Magnet Power Supply for HUST-PTF |
1269 |
|
- X.Y. Li, Y.Y. Hu, Y.J. Lin, P. Tan, X.D. Tu, Y.C. Yu, L.G. Zhang, Z.Q. Zhang
HUST, Wuhan, People’s Republic of China
|
|
|
An active scanning proton therapy facility is being de-veloped at Huazhong University of Science and Technol-ogy(HUST). By controlling the deflection position of the beam with scanning magnets at different times, the superposition of discrete spot beams will form a specified shape and dose distribution conformal to the target tu-mour. A high precision and fast response power supply is required to deflect the beam quickly and accurately. In this paper, the TOSCA module in Opera3D is used to model and simulate the scanning magnets and to obtain the equivalent inductance of the magnet. Then the calcu-lated equivalent resistance inductance instead of the magnet is used to design the scanning magnet power supply. A high-voltage bridge is utilized to achieve fast response speed, and a low voltage bridge and PI control algorithm is adopted to ensure power supply accuracy. The Simulation result shows that the designed power supply meets the requirements of response speed and accuracy.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPMP017
|
|
About • |
paper received ※ 30 April 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPTS046 |
Commissioning of a Compact THz Source Based on FEL |
2030 |
|
- Y.J. Pei, G. Feng, X.Y. He, Y. Hong, D. Jia, P. Lu, S. Lu, L. Shang, B.G. Sun, Zh.X. Tang, W. Wang, X.Q. Wang, W. Wei
USTC/NSRL, Hefei, Anhui, People’s Republic of China
- L. Cao, Q.S. Chen, Q. Fu, T. Hu, P. Tan, Y.Q. Xiong
HUST, Wuhan, People’s Republic of China
- G. Huang
IMP/CAS, Lanzhou, People’s Republic of China
- L.G. Shen, F. Zhang
USTC/PMPI, Hefei, Anhui, People’s Republic of China
|
|
|
The layout of the THz source based on FEL was de-scribed in this paper. The THz source was based on a FEL which was composed of a compact 8-14MeV LINAC, undulator, optical resonance, THz wave measurement system and so on. The facility was designed in 2013 and the typical running parameter got in 2017 were as the following: energy is of 12.7MeV, energy spread is of 0.3%, macro-pulse is of 4 μs, pulse length of micro-pulse is of 6ps, emittance is of 24 mm.mrad. After that the ma-chine was commissioning for production THz radiation. In November 2018, the THz wave was test and got THz wave signal, the spectrum was also got. This year, we plan to measure the output power of the THz source.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPTS046
|
|
About • |
paper received ※ 15 May 2019 paper accepted ※ 21 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPRB118 |
Study on the Influence of the Range Shifter Material in a Scanning Nozzle for Proton Therapy Based on Monte Carlo Method |
4100 |
|
- Y.C. Yu, H.D. Guo, Y.Y. Hu, X.Y. Li, Y.J. Lin, P. Tan, X.D. Tu, L.G. Zhang
HUST, Wuhan, People’s Republic of China
|
|
|
Range shifter plays a key role in decreasing the energy of the proton beam to realize shallow tumours treatment with the scanning nozzle in Huazhong University of Science and Technology Proton Therapy Facility (HUST-PTF). To control the transverse scattering and decrease the damage to healthy tissue caused by secondary particle, influence of the range shifter material was studied. In this paper, the Monte Carlo software Geant4 and FLUKA are applied to analyse the transport process of proton beam in the range shifters made of six different materials: PMMA, Lexan, Lucite, Polyethylene, Polystyrene, and Wax. The beam spot sizes at the iso-center with or without range shifter was calculated for the HUST-PTF scanning nozzle. The relationship between the thickness of the range shifters of the six materials and the proton energy was obtained. The secondary neutron yield at the end of the nozzle was also analysed.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPRB118
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|