Author: Tan, J.
Paper Title Page
WEPGW020 Next Generation Cryogenic Current Comparator (CCC) for nA Intensity Measurement 2510
 
  • T. Sieber, D.M. Haider, H. Reeg, M. Schwickert, T. Stöhlker
    GSI, Darmstadt, Germany
  • H. De Gersem, N. Marsic, W.F.O. Müller
    TEMF, TU Darmstadt, Darmstadt, Germany
  • J. Golm, F. Schmidl, P. Seidel, V. Tympel
    FSU Jena, Jena, Germany
  • M. Schmelz, R. Stolz, V. Zakosarenko
    IPHT, Jena, Germany
  • T. Stöhlker
    IOQ, Jena, Germany
  • T. Stöhlker
    HIJ, Jena, Germany
  • J. Tan, G. Tranquille
    CERN, Meyrin, Switzerland
 
  A Cryogenic Current Comparator (CCC) is an extremely sensitive DC-Beam Transformer based on superconducting SQUID technology. Recently, a CCC without a toroidal core and with an axially oriented magnetic shielding has been developed at the Institute of Photonic Technologies (IPHT) Jena/Germany. It represents a compact and lightweight alternative to the ’classical’ CCC, which was originally developed at PTB Braunschweig and is successfully in operation in accelerators at GSI and CERN. Excellent low-frequency noise performance was demonstrated with a prototype of this new CCC-type. Current measurements and further tests are ongoing, first results are presented together with simulation calculations for the magnetic shielding. The construction from lead as well as simplified manufacturing results in drastically reduced costs compared to formerly used Nb-CCCs. Reduced weight also puts less constraints on the cryostat. Based on highly sensitive SQUIDs, the new prototype device shows a current sensitivity of about 6 pA/Hz1/2 in the white noise region. The measured and calculated shielding factor is ~135 dB. These values, together with a significant cost reduction - resulting also from a compact cryostat design - opens up the way for widespread use of CCCs in modern accelerator facilities.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW020  
About • paper received ※ 13 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THYYPLS2 Different Versions of Cryogenic Current Comparators with Magnetic Core for Beam Current Measurements 3431
 
  • J. Golm, F. Schmidl, P. Seidel
    FSU Jena, Jena, Germany
  • H. De Gersem, N. Marsic, W.F.O. Müller
    TEMF, TU Darmstadt, Darmstadt, Germany
  • M.F. Fernandes, C.P. Welsch
    Cockcroft Institute, Warrington, Cheshire, United Kingdom
  • M.F. Fernandes, J. Tan, C.P. Welsch
    CERN, Meyrin, Switzerland
  • M.F. Fernandes, C.P. Welsch
    The University of Liverpool, Liverpool, United Kingdom
  • D.M. Haider, F. Kurian, M. Schwickert, T. Sieber, T. Stöhlker
    GSI, Darmstadt, Germany
  • R. Neubert
    Thuringia Observatory Tautenburg, Tautenburg, Germany
  • M. Schmelz, R. Stolz, V. Zakosarenko
    IPHT, Jena, Germany
  • T. Stöhlker
    IOQ, Jena, Germany
  • T. Stöhlker, V. Tympel
    HIJ, Jena, Germany
  • V. Zakosarenko
    Supracon AG, Jena, Germany
 
  For more than 20 years Cryogenic Current Comparators (CCC) are used to measure the current of charged particle beams with low intensity (nA-range). The device was first established at GSI in Darmstadt and was improved over the past two decades by the cooperation of institutes in Jena, GSI and CERN. The improved versions differ in material parameters and electronics to increase the resolution and in dimensions in order to meet the requirements of the respective application. The device allows non-destructive measurements of the charged particle beam current. The azimuthal magnetic field which is generated by the beam current is detected by low temperature Superconducting Quantum Interference Device (SQUID) current sensors. A complex shaped superconductor cooled down to 4.2 K is used as magnetic shielding and a high permeability core serves as flux concentrator. Three versions of the CCC shall be presented in this work: (1) GSI-Pb-CCC which was running at GSI Darmstadt in a transfer line, (2) CERN-Nb-CCC currently installed in the Antiproton Decelerator at CERN and (3) GSI-Nb-CCC-XD which will be operating in the CRYRING at GSI 2019. Noise, signal and drift measurements were performed in the Cryo-Detector Lab at the University of Jena.  
slides icon Slides THYYPLS2 [4.344 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THYYPLS2  