Paper | Title | Page |
---|---|---|
WEPGW103 | Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts | 2732 |
|
||
Funding: Work supported by National Science Foundation award PHY-1549132, the Center for Bright Beams. Fermi Research Alliance operates Fermilab under Contract DE-AC02-07CH11359 with the US Dept. of Energy. The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. A key part of its beam diagnostics suite are synchrotron radiation monitors, used for measuring transverse beam profile, position, and intensity. In this paper, we report on the performance and uses of this system during the year 1 run. We demonstrate sub-100nm statistical beam position uncertainty and high dynamic range from 109 electrons down to a single electron. Commissioning challenges and operational issues are discussed. We conclude by outlining current upgrade efforts, including improved modularity, small emittance measurements, and a multi-anode photomultiplier system for turn-by-turn acquisition. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW103 | |
About • | paper received ※ 15 May 2019 paper accepted ※ 19 May 2019 issue date ※ 21 June 2019 | |