Paper | Title | Page |
---|---|---|
TUPGW085 | A Hard X-Ray Compact Compton Source at CBETA | 1604 |
|
||
Compton backscattering at energy recovery linacs (ERLs) promises high flux, high energy x-ray sources in the future, made possible by high quality, high repetition rate electron beams produced by ERLs. CBETA, the Cornell-BNL ERL Test Accelerator currently being built and commissioned at Cornell, is an SRF multi-turn ERL using Non-Scaling Fixed Field Alternating-gradient (NS-FFA) arcs. CBETA has high quality design parameters with an anticipated top energy of 150 MeV on the fourth pass. The expected parameters of a Compton source at CBETA include a top x-ray energy of over 400 keV with a flux on the order of 1012 ph/s. In this paper, we present anticipated parameters and potential applications in science and engineering for this source. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPGW085 | |
About • | paper received ※ 14 May 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPMP054 | Superconducting Dipole Design for a Proton Computed Tomography Gantry | 3574 |
|
||
Funding: This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the MSC grant agreement No 675265, OMA - Optimization of Medical Accelerators. Proton computed tomography aims to increase the accuracy of proton treatment planning by directly measuring proton stopping power. This imaging technique requires a proton beam of 330 MeV incident kinetic energy for adult patients. Employing superconducting technology in the beam delivery system allows it to be of comparable size to a conventional proton therapy gantry. A superconducting bending magnet design for a proton computed tomography gantry is proposed in this paper. The 30 deg, 3.9 T canted-cosine-theta dipole wound with NbTi wires is used to steer 330 MeV protons in an isocentric beam delivery system which rotates around the patient. Two methods of magnetic field shielding are compared in the context of proton therapy facility requirements; traditional passive shielding with an iron yoke placed around the magnet and an active shielding option utilising extra layers of the superconducting coil. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPMP054 | |
About • | paper received ※ 15 May 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPGW070 | Design of the Cockcroft Beamline: Adjustable Transport of Laser Wakefield Electrons to an Undulator | 3749 |
SUSPFO114 | use link to see paper's listing under its alternate paper code | |
|
||
Funding: Work supported by U.K. STFC (Grant No. ST/G008248/1), EuPRAXIA (Grant No. 653782), ECs LASERLAB-EUROPE (Grant No. 654148), U.K. EPSRC (Grant No. EP/J018171/1, EP/J500094/1 and EP/N028694/1). The Cockcroft Beamline is being designed to transport 1 GeV electrons from a laser wakefield accelerator (LWFA) to an undulator at the Scottish Centre for the Application of Plasma-based Accelerators (SCAPA) in Glasgow, UK. To demonstrate undulator radiation in the X-ray spectral region and potentially free electron laser (FEL) gain, electrons should be transported between the LWFA and the undulators with high fidelity. In this paper we present the design of an adjustable beam line to transport LWFA electrons to the undulator for a range of energies, from 0.5 GeV to 1 GeV, while preserving the electron beam properties and matching the undulator-beam coupling. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPGW070 | |
About • | paper received ※ 15 May 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |