Paper |
Title |
Page |
MOPRB018 |
Conceptual Design of Negative-Muon Decelerator for Material Science |
610 |
|
- C. Ohmori, M. Otani, K. Shimomura
KEK, Tokai, Ibaraki, Japan
- T. Takayanagi
JAEA/J-PARC, Tokai-mura, Japan
|
|
|
In 2018, a Negative-Muon Spin Rotation and Relaxation technique was developed in J-PARC Material and Life Science Facility. It is a novel scheme to investigate the motion of hydrogens in the chemicals and materials. To study small samples, the surface of materials and thin foils, a low energy negative muon beam is required. To decelerate intense 300-keV muons to 15-keV, we propose a system which consists of pulse generators and multi-gap induction decelerators. In this design, an inductive adder scheme is considered to use for the high voltage pulse source. High impedance magnetic alloy ring cores will be loaded in the decelerator cells. The high impedance cores which have much larger size than those for public use were developed for J-PARC RF systems and used for many applications including CERN booster RF, anti-proton deceleration and medical accelerator. In this paper, we present a conceptual design of muon deceleration system.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-MOPRB018
|
|
About • |
paper received ※ 13 May 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPTS035 |
Vacuum Tube Operation Analysis for 1.2 MW Beam Acceleration in J-PARC RCS |
2017 |
|
- M. Yamamoto, M. Nomura, T. Shimada, F. Tamura
JAEA/J-PARC, Tokai-mura, Japan
- M. Furusawa, K. Hara, K. Hasegawa, C. Ohmori, Y. Sugiyama, M. Yoshii
KEK, Tokai, Ibaraki, Japan
|
|
|
The J-PARC RCS has successfully accelerated 1 MW proton beam, matching the designed beam power. Therefore, we have considered acceleration beyond the designed beam power, with the next target being 1.2 MW. An issue for 1.2 MW beam acceleration is the rf system. The present anode power supply is limited by its output current, and the vacuum tube amplifier suffers from an unbalance of the anode voltage swing, arising from the combination of multi-harmonic rf driving and push-pull operation. We have investigated the mitigation of the maximum anode currents and unbalanced tubes by choosing appropriate circuit parameters of the rf cavity with the tube amplifier. We describe the analysis results of the vacuum tube operation for 1.2 MW beam acceleration in the RCS.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPTS035
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 21 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPRB026 |
Simulations of Beam Loading Compensation in a Wideband Accelerating Cavity Using a Circuit Simulator Including a LLRF Feedback Control |
2863 |
|
- F. Tamura, M. Nomura, T. Shimada, M. Yamamoto
JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
- M. Furusawa, K. Hara, K. Hasegawa, C. Ohmori, Y. Sugiyama, M. Yoshii
KEK, Tokai, Ibaraki, Japan
|
|
|
Magnetic alloy cavities are employed in the J-PARC RCS to generate high accelerating voltages. The cavity, which is driven by a vacuum tube amplifier, has a wideband frequency response and the beam loading in the cavity is multiharmonic. Therefore, the tube must generate a multiharmonic output current. An LTspice circuit model is developed to analyze the vacuum tube operation and the compensation of the multiharmonic beam loading. The model includes the cavity, tube amplifier, beam current, and LLRF feedback control. The feedback control consists of the I/Q demodulator including low pass filters, PI control, and I/Q modulator. In this presentation, we present the implementation of the LLRF functions in the LTspice simulations. The preliminary simulation results are also presented. The simulations fairly agree with the beam test results.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-WEPRB026
|
|
About • |
paper received ※ 23 April 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPRB107 |
The New 1-18 MHz Wideband RF System for the CERN PS Booster |
3063 |
|
- M.M. Paoluzzi, L. Arnaudon, V. Bretin, Y. Cuvet, J. Daricou, S. Energico, M. Haase, A.J. Jones, D. Landré, C. Rossi
CERN, Geneva, Switzerland
- C. Ohmori
KEK/JAEA, Ibaraki-Ken, Japan
|
|
|
The LHC Injector Upgrade (LIU) project at CERN prepares the injectors to meet the requirements of the High Luminosity LHC. For protons, it includes the new Linac4, PS Booster (PSB), PS and SPS. Among the major changes concerning the PSB, the extraction energy increase from 1.4 GeV to 2 GeV and the higher beam intensity, made possible by the Linac4 together with the new charge exchange injection system into the PSB (2·1013 protons) strongly affect the RF system requirements. To deal with this more demanding beam operation, a new RF system was designed. It is based on modern magnetic alloy loaded cavities driven by solid-state amplifiers. Its wideband frequency response (1 MHz to 18 MHz) covers all the required frequency schemes. This new RF system has been produced in 2017 and 2018; installation is planned during 2019, the first year of Long Shutdown 2 (LS2) and commissioning foreseen in 2020. Most of the production and testing was outsourced to industry; parts acceptance, cavities assembly and pre-testing was done in-house. A quality assurance plan was established to achieve the required high reliability. This paper describes the procurement, production and testing strategies and methodologies. It also reports the achieved results, system performances and relevant statistics.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-WEPRB107
|
|
About • |
paper received ※ 26 April 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|