Paper |
Title |
Page |
THPRB068 |
Upgrade of CERN’s PSB Digital Low-Level RF System |
3958 |
|
- M.E. Angoletta, S.C.P. Albright, A. Findlay, M. Jaussi, J.C. Molendijk, N. Pittet
CERN, Meyrin, Switzerland
|
|
|
The CERN PS Booster (PSB) is the first circular accelerator in the LHC proton injector chain. The upgrade of this four-ring machine is underway within the framework of the LHC Injectors Upgrade project. The existing digital Low-Level RF (LLRF) system will also be upgraded. This paper outlines the LLRF capabilities required, their implementation and the challenges involved. Results of tests carried out to prepare for the LLRF upgrade are given.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPRB068
|
|
About • |
paper received ※ 13 May 2019 paper accepted ※ 18 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPRB069 |
The New Digital Low-Level RF System for CERN’s Extra Low Energy Antiproton Machine |
3962 |
|
- M.E. Angoletta, M. Jaussi, J.C. Molendijk
CERN, Geneva, Switzerland
|
|
|
CERN’s new Extra Low ENergy Antiproton accelerator/decelerator (ELENA) completed its initial commissioning in 2018. This machine is equipped with a new digital Low-Level RF (LLRF) system that implements beam and cavity loops as well as longitudinal diagnostics. ELENA’s LLRF was instrumental for machine commissioning by decelerating some 1 E7 antiprotons from 5.3 MeV to 100 keV. Commissioning with H− ions took also place. Challenges faced included coping with low beam intensity and the wide frequency swing. This paper gives an overview of the LLRF system capabilities and operation. Beam results achieved with both H− ions and antiprotons are also shown.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPRB069
|
|
About • |
paper received ※ 13 May 2019 paper accepted ※ 21 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPRB070 |
A New Digital Low-Level RF and Longitudinal Diagnostic System for CERN’s AD |
3966 |
|
- M.E. Angoletta, S.C.P. Albright, A. Findlay, M. Jaussi, J.C. Molendijk, V.R. Myklebust
CERN, Meyrin, Switzerland
|
|
|
The Antiproton Decelerator (AD) has been routinely providing 3 E7 antiprotons since July 2000 at 100 MeV/c from 3.5 GeV/c. It will be refurbished during the Long Shutdown 2 (LS2) to provide reliable operation for the new Extra Low ENergy Antiproton (ELENA) ring. AD will be equipped with a new digital Low-Level RF (LLRF) system before its restart in 2021. Diagnostics to measure beam intensity, Δp/p and Schottky spectra will also be developed. This paper is an overview of the planned capabilities and implementations, as well as of the challenges to overcome.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPRB070
|
|
About • |
paper received ※ 13 May 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|