Paper | Title | Page |
---|---|---|
TUPGW001 | Improvements to Injector System Efficiency at the Australian Synchrotron | 1378 |
|
||
Funding: Australian Nuclear Science and Technology Organisation New instrumentation, software, and hardware upgrades have allowed Operations personnel to increase the overall injector system efficiency from 50% to 80% at the Australian Synchrotron. This paper will provide an overview of the methods used to achieve this result. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPGW001 | |
About • | paper received ※ 15 May 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPRB001 | The Effect of the SLED Installation on Extracted and Lost Beam at the Australian Synchrotron Linac. | 2794 |
SUSPFO001 | use link to see paper's listing under its alternate paper code | |
|
||
A recent upgrade to the high power RF network of the linac at the Australian Synchrotron included a SLED Type 1 Pulse Compressor allowing for the operation of its 100 MeV linac using a single klystron. We explore the effects of the SLED installation on the properties of the beam extracted from the linac with a particular focus on the energy spread and bunch train profile. Additionally, the optical fibre beam loss monitor (oBLM), also recently commissioned, was employed to provide shot-by-shot feedback on loss location and intensity to investigate the change in beam losses. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPRB001 | |
About • | paper received ※ 15 May 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |