- P.W. Huang, Y. Chen, J.D. Good, M. Groß, I.I. Isaev, C. Koschitzki, M. Krasilnikov, S. Lal, X. Li, O. Lishilin, D. Melkumyan, R. Niemczyk, A. Oppelt, H.J. Qian, H. Shaker, F. Stephan, G. Vashchenko
DESY Zeuthen, Zeuthen, Germany
- D. Filippetto, F. Sannibale
LBNL, Berkeley, California, USA
- C.-X. Tang
TUB, Beijing, People’s Republic of China
- W. Wan
ShanghaiTech University, Shanghai, People’s Republic of China
|
|
|
In state of the art photoinjector electron sources, cathode performance determines the lower limit of achievable beam emittance. Measuring the thermal emittance at the photocathodes in electron guns is of vital importance for improving the injectors. Traditional methods, like solenoid scan, pepper-pot, need multi-shots and are time-consuming, therefore suffer from machine stability. Here we propose a new method, named cathode transverse momentum imaging. By tuning the gun solenoid focusing, the electrons’ transverse momentum at the cathode is imaged to a downstream screen, which enables a single shot measurement. Several experiments have been done at the Photo Injector Test Facility at DESY in Zeuthen (PITZ) with a Cs2Te cathode. Measurements of cathode transverse momentum, the corresponding spectra, cathode transverse momentum map and its correlation with surface electric field are presented.
|
|