The measurement accuracy of direct current-current transformer (DCCT) is one of the key factors influencing the output of high-precision direct current power supply. In this paper, a calibration system designed by measuring resistance principle with a high accuracy direct current comparator (DCC) was presented for DCCT whose measurement accuracy is better than 10-5. The system can achieve high-precision calibration of DCCT within the measurement range of 0-400 A, and the uncertainty of the system calibration is better than 1.1×10-6 in the whole range. The accuracy and linearity of DCCT are tested to verify the accuracy of the whole calibration system, thereby the current accuracy of the magnet power supply can be further improved.
|
|