TUPRB025 Harmonic Lasing of the European XFEL in the Angstrom Regime 1740
 
  • E. Schneidmiller, F. Brinker, W. Decking, D. Nölle, M.V. Yurkov, I. Zagorodnov
    DESY, Hamburg, Germany
  • N. Gerasimova, J. Grünert, N.G. Kujala, J. Laksman, Y. Li, J. Liu, Th. Maltezopoulos, I. Petrov, L. Samoylova, S. Serkez, H. Sinn, F. Wolff-Fabris
    EuXFEL, Schenefeld, Germany
 
  Harmonic lasing in XFELs is an opportunity to extend the photon energy range of existing and planned X-ray FEL user facilities. Contrary to nonlinear harmonic generation, harmonic lasing can provide much more intense, stable, and narrow-band FEL beam. Another interesting application is Harmonic Lasing Self-Seeding (HLSS) that allows to improve longitudinal coherence and spectral power of a Self-Amplified Spontaneous Emission (SASE) FEL. This concept was successfully tested at FLASH2 in the range of 4.5 - 15 nm and at PAL XFEL at 1 nm. In this contribution we present recent results from the European XFEL where we successfully demonstrated operation of HLSS FEL at 5.9 A, thus pushing harmonic lasing for the first time into the Angstrom regime.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPRB025  
About • paper received ※ 09 May 2019       paper accepted ※ 23 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPGW051 MCP Based Detectors of European XFEL 3703
 
  • E. Syresin, O.I. Brovko, A.Yu. Grebentsov
    JINR, Dubna, Moscow Region, Russia
  • W. Freund, J. Grünert
    EuXFEL, Schenefeld, Germany
  • M.V. Yurkov
    DESY, Hamburg, Germany
 
  Radiation detectors based on microchannel plates (MCP) are used for measurements of the SASE process of the European XFEL. Detectors operate in a wide dynamic range from the level of spontaneous emission to the saturation level (between a few nJ and 25 mJ) and in a wide wavelength range from 0.05 nm to 0.4 nm for SASE1 and SASE2 and from 0.4 nm to 4.43 nm for SASE3. Photon pulse energies are measured by the MCPs with an anode and by a photodiode. The MCP imager measures the photon beam image with a phosphor screen. Three MCP detectors are installed, one behind each SASE undulator (SASE1, SASE2, and SASE3). Calibration and first experiments with the MCP detectors are under discussion.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPGW051  
About • paper received ※ 29 April 2019       paper accepted ※ 23 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)