Author: Gauthier, F.
Paper Title Page
FRXXPLS1 Tests of a 3D Printed BPM with a Stretched Wire and with a Particle Beam 4368
 
  • N. Delerue, D. Auguste, J. Bonis, F. Gauthier, S. Jenzer, A.M. Moutardier
    LAL, Orsay, France
 
  Funding: CNRS/IN2P3
We have successfully printed a beam position monitor using 3D printing. After ultra-high vacuum testing and initial measurements with a network analyser we now reports on tests of this BPM using the stretched wire method. The BPM has been installed on a test stand with a wire going through it and electrical pulses have been sent. The signal measured on the pick-ups was compared to that of two conventional BPMs and shows no anomaly specific to the 3D printed BPMs. Following the success of these tests we have also installed this BPM in a beam line at the PhotoInjector at LAL (PHIL). We show that it can give position measurements with an accuracy comparable to that of other BPMs.
 
slides icon Slides FRXXPLS1 [29.118 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-FRXXPLS1  
About • paper received ※ 19 May 2019       paper accepted ※ 22 May 2019       issue date ※ 21 June 2019  