Author: Egawa, K.
Paper Title Page
MOPMP006 Magnetic Measurement With Single Stretched Wire Method on SuperKEKB Final Focus Quadrupoles 432
 
  • Y. Arimoto, K. Egawa, T. Kawamoto, M. Masuzawa, Y. Ohsawa, N. Ohuchi, R. Ueki, X. Wang, H. Yamaoka, Z.G. Zong
    KEK, Ibaraki, Japan
  • J. DiMarco, J.M. Nogiec, G. Velev
    Fermilab, Batavia, Illinois, USA
 
  Superconducting-final-focus-quadrupole magnet system (QCS) were installed on an interaction region (IR) of SuperKEKB on Feb. 2017. The QCS consists of eight quadrupole magnets and four compensation solenoids; these magnets are contained in the two cryostats and are installed into Belle II detector which generates a solenoid field of 1.5 T. We determined the quadrupole centers with respect to accelerator beam lines with a single stretched wire (SSW) method. Here the results of the magnetic measurement with SSW are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-MOPMP006  
About • paper received ※ 15 May 2019       paper accepted ※ 23 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)