Author: Edwards, A.V.
Paper Title Page
WEPRB063 Connection of 12 GHz High Power RF from the XBOX 1 High Gradient Test Stand to the CLEAR Electron LINAC 2960
 
  • A.V. Edwards
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • N. Catalán Lasheras, S. Gonzalez Anton, G. McMonagle, S. Pitman, B.J. Woolley, V. del Pozo Romano
    CERN, Meyrin, Switzerland
 
  A new RF system is being established at XBOX1 to drive two §I{100}{MV/m} CLIC structures in the CLEAR electron linac. In the past, these structures had been powered by RF from PET structures excited by a drive beam. This drive beam is no longer available. The upgrade will reroute power from the §I{50}{MW} klystron and pulse compressor which was previously used to power the structure in XBOX1. During the upgrade, the LLRF system will be optimised to improve the modulation of the output signals and down-mixing of the returning signals to obtain accurate phase and amplitude information. The design of the improved LLRF and software, along with phase noise measurements and comparisons with the old system are made in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPRB063  
About • paper received ※ 14 May 2019       paper accepted ※ 22 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)