Author: Cornelis, K.
Paper Title Page
MOPGW072 Reconfiguration of SPS Landau Octupole Circuits to Minimise Second Order Chromaticity 262
 
  • H. Bartosik, M. Carlà, K. Cornelis
    CERN, Geneva, Switzerland
 
  In the SPS Q20 optics presently used for LHC beams, the Landau octupole families of the SPS (LOF and LOD circuits) generate large second order chromaticity due to the relatively high dispersion at their locations. Since the induced second order chromaticity results in enhanced losses due to the large incoherent tune spread, these octupoles cannot be used for mitigating transverse instabilities for LHC beams. A new cabling scheme was proposed, exploiting additional octupoles that were already installed in the machine but not used, which allows minimizing the induced second order chromaticity in both the Q20 optics used for LHC beams, as well as the original SPS optics used for fixed target beams. This paper summarises the optics calculations as well as the experimental verification of the reduced chromatic detuning of the new octupole scheme.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-MOPGW072  
About • paper received ※ 12 May 2019       paper accepted ※ 17 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMP031 SPS Slow Extraction Losses and Activation: Update on Recent Improvements 2391
 
  • M.A. Fraser, B. Balhan, H. Bartosik, J. Bernhard, C. Bertone, D. Björkman, J.C.C.M. Borburgh, M. Brugger, N. Charitonidis, N. Conan, K. Cornelis, Y. Dutheil, L.S. Esposito, R. Garcia Alia, L. Gatignon, C.M. Genton, B. Goddard, C. Heßler, Y. Kadi, V. Kain, A. Mereghetti, M. Pari, M. Patecki, J. Prieto, S. Redaelli, F. Roncarolo, R. Rossi, W. Scandale, N. Solieri, J. Spanggaard, O. Stein, L.S. Stoel, F.M. Velotti, H. Vincke
    CERN, Meyrin, Switzerland
  • D. Barna, K. Brunner
    Wigner Research Centre for Physics, Institute for Particle and Nuclear Physics, Budapest, Hungary
 
  Annual high intensity requests of over 1019 protons on target (POT) from the CERN Super Proton Synchrotron (SPS) Fixed Target (FT) physics program continue, with the prospect of requests for even higher, unprecedented levels in the coming decade. A concerted and multifaceted R&D effort has been launched to understand and reduce the slow extraction induced radioactivation of the SPS and to anticipate future experimental proposals, such as SHiP* at the SPS Beam Dump Facility (BDF)**, which will request an additional 4·1019 POT per year. In this contribution, we report on operational improvements and recent advances that have been made to significantly reduce the slow extraction losses, by up to a factor of 3, with the deployment of new extraction concepts, including passive and active (thin, bent crystal) diffusers and extraction on the third-integer resonance with octupoles. In light of the successful tests of the prototype extraction loss reduction schemes, an outlook and implications for future SPS FT operation will be presented.
* A. Golutvin et al., Rep. CERN-SPSC-2015-016 (SPSC-P-350), CERN, Geneva, Switzerland, Apr. 2015.
** M. Lamont et al., Rep. CERN-PBC-REPORT-2018-001, CERN, Geneva, Switzerland, 11 Dec 2018.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPMP031  
About • paper received ※ 14 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPMP034 Characterisation of SPS Slow Extraction Spill Quality Degradation 2403
 
  • F.M. Velotti, H. Bartosik, M.C.L. Buzio, K. Cornelis, V. Di Capua, M.A. Fraser, B. Goddard, V. Kain
    CERN, Meyrin, Switzerland
 
  The main physics users of the Super Proton Synchrotron (SPS) are the experiments installed in the North Area (NA). They are supplied with slowly extracted protons or heavy ions, exploiting a third integer slow extraction to provide a 4.8 s spill. High duty cycle and constant particle flux are the main requirements. Frequent super cycle changes induce variation of the spill macro structure which directly deteriorate the final spill quality. In this paper, the source of such an effect are investigated. Results of both beam based measurements and direct magnetic measurements on the SPS reference magnets are presented. Finally, a possible strategy to counteract this effect is discussed, in order to try to remove the super cycle changes variation as cause for spill quality deterioration.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPMP034  
About • paper received ※ 15 May 2019       paper accepted ※ 21 May 2019       issue date ※ 21 June 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)