Paper | Title | Page |
---|---|---|
WEZZPLS2 | EuPRAXIA, a Step Toward a Plasma-Wakefield Based Accelerator With High Beam Quality | 2291 |
|
||
Funding: European Union’s Horizon 2020 research and innovation programme under grant agreement No. 653782 The EuPRAXIA project aims at designing the world’s first accelerator based on plasma-wakefield advanced technique, which can deliver a 5 GeV electron beam with simultaneously high charge, low emittance and low energy spread to user’s communities. Such challenging objectives can only have a chance to be achieved when particular efforts are dedicated to identify the subsequent issues and to find the way to solve them. Many injection/acceleration schemes and techniques have been explored by means of thorough simulations in more than ten European institutes to sort out the most appropriate ones. The specific issues of high charge, high beam quality and beam extraction then transfer to the user’s applications, have been tackled with many innovative approaches*. This article highlights the different advanced methods that have been employed by the EuPRAXIA collaboration and the preliminary results obtained. The needs in terms of laser and plasma parameters for such an accelerator are also summarized. *- in 2017: Phys. Plasmas, 24,10,103120; Nat. Commun.8,15705; - in 2018: NIMA, 909,84-89; NIMA, 909,49-53; Phys. Rev.Acc. Beams, 21,111301; NIMA, 909,54-57; Phys. Rev.Acc. Beams, 21,052802; NIMA, 909,282-285 |
||
![]() |
Slides WEZZPLS2 [5.157 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEZZPLS2 | |
About • | paper received ※ 12 April 2019 paper accepted ※ 17 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPRB106 | Simulation of the Transition Radiation Transport Through an Optic System | 3059 |
SUSPFO036 | use link to see paper's listing under its alternate paper code | |
|
||
Optical Transition Radiation (OTR) screens are widely used for beam profile measurements. The radiation is emitted when a charged particle beam crosses the boundary between two media with different optical properties. The main advantages of OTR are the instantaneous emission process allowing fast single shot measurements (i.e. bunch by bunch measurements in a multi bunch machine), and the good linearity with the beam charge (if coherent effects can be neglected). Furthermore, OTR angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor beam envelope, one may perform a distributed energy measurement along the machine: this will be useful, for instance, during the commissioning phase of a machine. This paper deals with the studies of an algorithm to optimize the generation and the transport of the transition radiation through an optic system using the simulation tool Zemax. The algorithm, in combination with a particle tracking code (i.e. Elegant), will allow to simulate the radiation generated by a beam and, so, to take into account beam divergence and energy spread or chromatic effects in the optic system. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPRB106 | |
About • | paper received ※ 08 May 2019 paper accepted ※ 21 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPGW025 | Facility Considerations for a European Plasma Accelerator Infrastructure (EuPRAXIA) | 3635 |
|
||
Funding: This work was supported by the European Union‘s Horizon 2020 research and innovation programme under grant agreement No. 653782. EuPRAXIA (European Plasma Research Accelerator with eXcellence In Applications) is a conceptual design study for a compact European infrastructure with multi-GeV electron beams based on plasma accelerators. The concept foresees two main experimental sites, one at INFN in Frascati and one at DESY in Hamburg. In Frascati, an RF injector based on S-band and X-band technology (electron energy up to 1 GeV) will be constructed and used as a drive beam for beam driven plasma acceleration (PWFA) with final electron beam energies up to 5 GeV. At DESY, the focus will be on laser driven plasma acceleration (LWFA) and an RF injector based on S-band technology (electron energy up to 240 MeV) or alternatively a plasma injector (electron energy up to 150 MeV) can be used before the beam is injected into the plasma accelerator for external LWFA and acceleration up to 5 GeV. A single stage approach based on LWFA with internal injection will also be pursued in a second beamline. User areas at both sites will provide access to FEL pilot experiments, positron generation, compact radiation sources, and test beams for HEP detector development. This contribution discusses facility space considerations for the future plasma accelerator research infrastructure of EuPRAXIA. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPGW025 | |
About • | paper received ※ 13 May 2019 paper accepted ※ 24 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
THPGW026 | Status of the Horizon 2020 EuPRAXIA Conceptual Design Study | 3638 |
|
||
Funding: This work was supported by the European Union’s Horizon 2020 Research and Innovation programme under grant agreement No. 653782. The Horizon 2020 Project EuPRAXIA (European Plasma Research Accelerator with eXcellence In Applications) is producing a conceptual design report for a highly compact and cost-effective European facility with multi-GeV electron beams accelerated using plasmas. EuPRAXIA will be set up as a distributed Open Innovation platform with two construction sites, one with a focus on beam-driven plasma acceleration (PWFA) and another site with a focus on laser-driven plasma acceleration (LWFA). User areas at both sites will provide access to FEL pilot experiments, positron generation and acceleration, compact radiation sources, and test beams for HEP detector development. Support centres in four different countries will complement the pan-European implementation of this infrastructure. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-THPGW026 | |
About • | paper received ※ 26 April 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |