Paper | Title | Page |
---|---|---|
MOPGW114 | Bayesian Approach for Linear Optics Correction | 390 |
|
||
With a Bayesian approach, the linear optics correction algorithm for storage rings is revisited. In modern ring-based accelerators, optics corrections are determined from repetitive measurements which help identify systematic and random quadrupole errors in presence of various measurement noises. This process is a multivariate nonlinear regression problem driven by either a completed lattice model or a Jacobian matrix. Starting from the Bayes’ theorem, ’likelihood functions’ and ’prior probability’ distributions are extracted from a complete linear optics model. Under some assumptions, the least square algorithm and then the Jacobian matrix approach can be re-derived. The coherence of the correction algorithm is ensured through specifying a self-consistent regularization coefficient to prevent overfitting. Optimal weights for different correction objectives are obtained based on their measurement noise level. A new technique has been developed to resolve degenerated quadrupole errors when observed at a few select BPMs. A necessary condition of being distinguishable is that their optics response vectors seen at these specific BPMs should be near-orthogonal. | ||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-MOPGW114 | |
About • | paper received ※ 18 April 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPGW102 | Investigation on Mysterious Long-Term Orbit Drift at NSLS-II | 2728 |
|
||
Funding: The study is supported by U.S. DOE under Contract No. DE-SC0012704. Over a few months in 2018, we observed occasional episodes of relatively quick accumulation of correction strengths for the fast correctors (used by the fast orbit feedback) near Cell 4 (C04) region at NSLS-II Storage Ring. We immediately started investigating the problem, but the cause remained unclear. However, after coming back from the Fall shutdown, we experienced even faster drifts, at a rate of as much as 10 urad per day in terms of orbit kick angle accumulation. The risk of damage on the ring vacuum chambers by the continuing orbit drift without explanation eventually forced us to take emergency study shifts and temporarily lock out the C04 IVU beamline. After extensive investigation by many subsystem experts in Accelerator Division, ruling out many suspicious sources one by one, we were finally able to conclude the cause to be the localized ground motion induced by large temperature jumps of the utility tunnel right underneath the C04 straight section. We report the details of this incident. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW102 | |
About • | paper received ※ 19 May 2019 paper accepted ※ 20 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEPGW114 | Interferometric Measurement of Bunch Length of a 3Mev Picocoulomb Electron Beam | 2766 |
|
||
Funding: BNL LDRD We report the bunch length measurement of low-energy 3 MeV electron beams in picosecond regime with the charge from 1.0 to 14 pC. It is the first time that we demonstrate single-cycle nano-joule coherent terahertz (THz) radiation from 3MeV electron beam can be meas-ured via a far-infrared Michelson interferometer using a QOD. At this low energy range, when charge is about 1 pC, the signal from the conventional helium-cooled sili-con composite bolometer is too low. Compared to the bunch length measurement via the ultrafast-laser-pump and electron-beam-probe in the timescale 10-14 to 10-12 s which is determined by the phase-transition dynamics in solids, the advantages are: there are no needs of pump laser and probe sample, greatly simplifying the experi-ment; the timing jitter between laser and electron beams contributes no error to the bunch length measurement; furthermore, the method can be extended to sub-picosecond regime enabling bunch length measurement in a much broader timescale 10-14 to 10-11 s for low-energy electron beams. In the current experiment the bunch length is limited to 1 ps only because the setup of driving laser to cathode with a large 70° incident angle, effective-ly lengthening the laser pulse to ≥1 ps. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-WEPGW114 | |
About • | paper received ※ 14 May 2019 paper accepted ※ 23 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |