Optics Calibration for Routine Operations In Taiwan Photon Source |
335 |
|
- F.H. Tseng, C.H. Chen, P.J. Chou
NSRRC, Hsinchu, Taiwan
|
|
|
To ensure a stable performance of Taiwan Photon Source (TPS), we perform the calibration of accelerator optics using LOCO (Linear Optics from Closed Orbit) technique every month. After the optics and coupling corrections, the rms beta beatings in both planes are reduced to less than 1%. The emittance coupling ratio is also restored to within the design value.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-MOPGW093
|
|
About • |
paper received ※ 06 May 2019 paper accepted ※ 18 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPGW071 |
Optimization and Measurements on the Double Mini-Betay Lattice in the TPS Storage Ring |
1567 |
|
- M.-S. Chiu, B.Y. Chen, C.H. Chen, J.Y. Chen, Y.-S. Cheng, P.C. Chiu, P.J. Chou, T.W. Hsu, K.H. Hu, J.C. Huang, P.Y. Huang, C.-C. Kuo, T.Y. Lee, C.Y. Liao, W.Y. Lin, Y.-C. Liu, H.-J. Tsai, F.H. Tseng
NSRRC, Hsinchu, Taiwan
|
|
|
The Taiwan Photon Source (TPS) is capable of operat-ing in multi-bunch and single-bunch mode. To operate in a hybrid mode as requested by users, we developed a lattice with chromaticities of 0.8/2 (x/y) to provide higher single bunch currents. Beam dynamics simulations and lattice characterizations including dynamic aperture, frequency map analysis, tune shift with energy, tune shift with amplitude, and betatron coupling will be discussed in this report.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPGW071
|
|
About • |
paper received ※ 30 April 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
TUPRB081 |
Beam Motion and Photon Flux Dips during Injection at the Taiwan Photon Source |
1848 |
|
- C.H. Huang, H.-P. Chang, C.H. Chen, Y.-S. Cheng, P.C. Chiu, C.-S. Fann, K.T. Hsu, K.H. Hu, C.Y. Liao, Y.-C. Liu, C.Y. Wu
NSRRC, Hsinchu, Taiwan
|
|
|
The Taiwan photon source (TPS) is a 3 GeV synchrotron light source now in routine operation at the NSRRC. At the beginning of beam commissioning, significant photon flux dips could be observed at injection due to a blow-up of the beam size. To eliminate this transient effect, all four kickers were rematched. The leakage field was shielded and the induced current loops at vacuum chambers in the injection area were also eliminated. These efforts reduced the horizontal betatron oscillations and orbit distortions to around one-tenth. In order to decrease the recovery time of photon dips during injection, the operational chromaticity was reduced to improve incoherent effects. After all those improvements, the photon flux dips during injection dropped to 30 % and the recovery time to less than 1 msec.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-TUPRB081
|
|
About • |
paper received ※ 17 April 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPTS053 |
Frequency Map Measurements at the TPS |
3240 |
|
- C.H. Chen, B.Y. Chen, J.Y. Chen, M.-S. Chiu, P.J. Chou, T.W. Hsu, B.Y. Huang, C.-C. Kuo, W.Y. Lin, Y.-C. Liu, H.-J. Tsai, F.H. Tseng
NSRRC, Hsinchu, Taiwan
|
|
|
Taiwan Photon Source (TPS) has been operated for several years since it’s first light in December 2014. TPS has achieved reliable routine operation at 500 mA with more than 10 hrs beam lifetime. The dynamic aperture measurements and associated Frequency Map Analyses (FMA) at TPS reveal the beam dynamics behavior with and without insertion devices. A preliminary measurement study by using the turn-by-turn BPMs and comparison with the model simulation results will be presented in this paper.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-WEPTS053
|
|
About • |
paper received ※ 30 April 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
THPTS070 |
Diagnostic Tool For CompactPCI Crates |
4275 |
|
- H.Z. Chen, C.H. Chen, Y.-S. Cheng, K.T. Hsu, K.H. Hu, C.Y. Liao, C.Y. Wu
NSRRC, Hsinchu, Taiwan
|
|
|
On the control system hardware platform for the Taiwan Photon Source (TPS) more than half use CompactPCI crates. If a crate malfunctions, the internal crate card will not operate properly affecting accelerator operation. If the crate, however, could provide instant remote operational information, an opportunity exists to maintain or replace it in advance. Therefore, a diagnostic tool was developed to analyse and diagnose the condition of the crates. When abnormal operations occur, an alarm can be issued for early inspection and maintenance. This way it is possible to prevent the EPICS IOC from crashing by CompactPCI crates, which improves the reliability of accelerator operation. A detailed system architecture, implementation and progress will be discussed in this report.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2019-THPTS070
|
|
About • |
paper received ※ 14 May 2019 paper accepted ※ 22 May 2019 issue date ※ 21 June 2019 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|