Paper | Title | Page |
---|---|---|
TUPTS008 | The Pulsing Chopper-Based System of the Arronax C70XP Cyclotron | 1948 |
|
||
Funding: This work is, in part, supported by a grant from the French National Agency for Research called "Investissements d’Avenir", Equipex Arronax-Plus noANR-11-EQPX-0004 and LabexIRON noANR-11-LABX-18-01. The Arronax Public Interest Group (GIP) uses a multi-particle cyclotron to perform irradiation from a few pA up to hundreds of uA on various experiments and targets *. To support further low intensity usage and extend the beam time structure required for experiments such as pulsed experiments studies (radiolysis, proton therapeutic irradiation) and high intensity impact studies, it has been devised a pulsing system in the injection of the cyclotron. This system combines the use of a chopper, low frequency switch, and a control system based on the new extended EPICS network. This paper details the pulsing system adopted at Arronax, the last results in terms of time structure, various low intensity experimental studies performed with alpha and proton beams and the dedicated photon diagnostics. * F.Poirier et al., "Studies and Upgrades on the C70 Cyclotron Arronax", CYC16, September 2016, TUD02. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2019-TUPTS008 | |
About • | paper received ※ 12 May 2019 paper accepted ※ 21 May 2019 issue date ※ 21 June 2019 | |
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |